DOI 10.13107/jocr.2024.v14.i09.4768
Management of Non-Union Distal Femur Fracture with Augmentation Nail-Plate Construct: A Case Report.
Аннотация
INTRODUCTION
Non-union fractures of the distal femur pose significant challenges in orthopedic surgery, often requiring revision procedures to achieve successful bone healing. In cases where the initial implant has failed, innovative solutions are necessary to promote bone union and functional recovery.
CASE REPORT: We present a case of a non-union distal femur fracture in a 22-year-old male patient, with a broken implant in situ. The patient had previously undergone internal fixation with a locking plate, which subsequently failed to promote bone healing. The patient was reoperated using a supracondylar nail and augmented with a distal femur locking plate to address the non-union. The combination of the supracondylar nail and distal femur locking plate successfully provided stability to the fracture site, promoting bone union and enabling functional recovery. Radiographic evidence and clinical assessment demonstrated excellent healing progress.
CONCLUSION
This case report highlights the importance of individualized treatment for non-union distal femur fractures, especially when prior implant failure occurs. The combined approach of a supracondylar nail and distal femur locking plate can be a valuable option in addressing complex non-union fractures, achieving stable fixation, and facilitating successful bone healing.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.