MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4055/cios24387

Медицинская библиотека · Clinics in orthopedic surgery · 2025

Radiological Parameters for Predicting the Risk of Flexor Tendon Rupture after Volar Plate Fixation for Distal Radius Fracture.

Park Il-Jung, Park Hyun Woo, Oh Seungbae, Kang Soo-Hwan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

In this study, we aimed to investigate postoperative radiographic parameters for predicting flexor tendon rupture after volar plate fixation for distal radius fractures.

METHODS

In this retrospective cohort study, postoperative radiographs of 15 cases of flexor tendon rupture were included as a flexor tendon rupture group. Additionally, data from 45 patients with non-flexor tendon rupture (control group), matched in terms of age, sex, and fracture type (1 : 3) to the flexor tendon rupture group, were reviewed in terms of fracture reduction and plate position. We assessed the Soong grade, plate-to-critical line distance (PCLD), and plate-to-volar rim distance to determine plate position and used other parameters to analyze anatomical reduction including radial tilt, ulnar variance, coronal carpal translation, radius-radial styloid distance, volar tilt, sagittal carpal alignment (SCA), and radius-volar lip distance (RVLD).

RESULTS

We identified 3 significant predictive factors for flexor tendon rupture after volar plate fixation for distal radius fractures. The mean PCLD and SCA were significantly greater in the flexor tendon rupture group than in the control group (p < 0.001). The mean RVLD was smaller in the flexor tendon rupture group than in the control group (p = 0.033). Logistic regression analysis was performed to examine the importance of the variables.

CONCLUSIONS

Our findings underscore the importance of PCLD, SCA, and RVLD as significant risk factors for flexor tendon rupture. Accurate plate positioning, achieving appropriate anatomical reduction, and vigilant monitoring for signs of plate irritation in high-risk patients may help prevent flexor tendon rupture.

Для цитирования: Park Il-Jung, Park Hyun Woo, Oh Seungbae, Kang Soo-Hwan. Radiological Parameters for Predicting the Risk of Flexor Tendon Rupture after Volar Plate Fixation for Distal Radius Fracture.. Clinics in orthopedic surgery. 2025. DOI: 10.4055/cios24387.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.