MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4055/cios24407

Медицинская библиотека · Clinics in orthopedic surgery · 2025

Automatic Assessment of Radiological Parameters of the Distal Radius Using a Hybrid Approach Combining Deep Learning and a Computer-Aided Diagnostic Algorithm.

Lee Sang-Jeong, Kang Minji, Lee Jae-Sung, Kang Kyu-Tae, Jung Hyoung-Seok

СтатьяПеревод в очереди

Аннотация

BACKGROUD: The use of deep learning algorithms in medical imaging has increased rapidly. This study aimed to develop an automated, hybrid approach combining a deep learning architecture and a conventional computer-aided diagnostic method to detect anatomical landmarks and measure radiological parameters in wrist radiography.

METHODS

Overall, 487 wrist radiographs were randomly sampled for training and validation, and 100 radiographs collected from 2 institutions were used as the test set. Anatomical landmarks for 4 commonly used parameters, namely, radial inclination (RI), radial length (RL), volar tilt (VT), and ulnar variance (UV), were identified and labeled. A 2-step hybrid method combining a deep learning model with conventional computer-aided diagnosis was developed to measure radiological parameters using these anatomical landmarks. Measurements were obtained from the test set. The mean value of each parameter determined by 2 hand surgeons served as the reference standard. The performance of the deep learning algorithm was evaluated using the successful detection rate (SDR), mean absolute error (MAE), intraclass correlation coefficient (ICC), and Pearson correlation coefficient (r).

RESULTS

The SDR of the model ranged from 97% to 98% at the 1 mm threshold and 99% at the 2 mm threshold. The RI, RL, VT, and UV generated by the model were 26.41° ± 4.01°, 12.63 ± 2.72 mm, 14.01° ± 8.02°, and 2.09 ± 2.76 mm, respectively. The overall MAEs for RI, RL, VT, and UV between the manually and automatically measured parameter values were 1.62° ± 1.26°, 1.56 ± 1.23 mm, 1.88° ± 1.68°, and 0.43 ± 0.41 mm, respectively. In the correlation analysis, good or high reliability was observed for RI, VT, and UV (ICC: 0.86, 0.95, and 0.98; r = 0.86, r = 0.95, and r = 0.98, respectively), and moderate reliability was observed for RL (ICC: 0.75, r = 0.78).

CONCLUSIONS

This novel automated hybrid method can accurately identify landmarks on wrist radiographs and automatically generate the radiological parameters of the distal radius. This method saves time and reduces human labor in creating datasets for training segmentation models and developing image processing algorithms.

Для цитирования: Lee Sang-Jeong, Kang Minji, Lee Jae-Sung, Kang Kyu-Tae, Jung Hyoung-Seok. Automatic Assessment of Radiological Parameters of the Distal Radius Using a Hybrid Approach Combining Deep Learning and a Computer-Aided Diagnostic Algorithm.. Clinics in orthopedic surgery. 2025. DOI: 10.4055/cios24407.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.