MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2017.06.037

Медицинская библиотека · Journal of shoulder and elbow surgery · 2017

Early results of Latitude primary total elbow replacement with a minimum follow-up of 2 years.

Mehta Saurabh S, Watts Adam C, Talwalkar Sumedh C, Birch Ann, Nuttall David, Trail Ian A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to present outcomes of primary Latitude total elbow replacement (TER) with a minimum follow-up of 2 years.

METHODS

A retrospective cohort study was undertaken with prospective outcome data collection for the latest outcome. Included were 63 consecutive primary Latitude TERs in 58 patients performed during a period of 5 years at a specialist orthopedic hospital.

RESULTS

The mean age of the patients was 62 years (33-85 years). Five primary TERs (4 patients) were lost to follow-up. The primary diagnosis was rheumatoid arthritis in 49, osteoarthritis in 8, and trauma in 6 elbows. The mean flexion-extension arc was 75° preoperatively and 97° postoperatively. Mean postoperative Elbex pain score was 19/100, and function score was 37/100. Mean postoperative scores were 42/100 for the Quick Disabilities of the Arm, Shoulder, and Hand and 38/50 for the elbow-specific American Shoulder and Elbow Surgeons assessment. Four patients died of unrelated causes, and 8 of 63 underwent further surgical intervention, including explantation and conversion from unlinked to linked implant. On radiographic review of 41 surviving TERs, aseptic radiologic loosening was observed of the humeral component in 4 elbows and of the ulnar component in 9. Seven elbows had no radial component, and of the remaining 34 elbows, 16 (47%) had signs of loosening of the radial implant. Complications included 1 heterotopic ossification, 1 olecranon fracture, and 3 further procedures for ulnar nerve entrapment.

CONCLUSION

The results indicate that the early outcome of Latitude TER is comparable to that of other prostheses. There is concern about early radiologic loosening of the radial component.

Для цитирования: Mehta Saurabh S, Watts Adam C, Talwalkar Sumedh C, Birch Ann, Nuttall David, Trail Ian A. Early results of Latitude primary total elbow replacement with a minimum follow-up of 2 years.. Journal of shoulder and elbow surgery. 2017. DOI: 10.1016/j.jse.2017.06.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.