MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0040-1713896

Медицинская библиотека · The journal of knee surgery · 2020

The Effect of Patellar Positioning on Femoral Component Rotation when Performing Flexion Gap Balancing Using a Tensioning Device for Total Knee Arthroplasty.

Ernstbrunner Lukas, Andronic Octavian, Grubhofer Florian, Jundt-Ecker Michèle, Fucentese Sandro F

СтатьяПеревод в очереди

Аннотация

There is an increasing interest in new devices such as tensiometers for flexion gap balancing during total knee arthroplasty (TKA). The purpose of this study was to determine the influence of patella positioning during flexion gap balancing on femoral component rotation. We prospectively evaluated 32 consecutive knees in 31 patients who underwent primary TKA for degenerative osteoarthritis and where soft tissue balancing was performed using the same tensiometer. Preoperative measurements included valgus/varus deformation, mechanical axis, epicondylar axis, and tibial slope. Intraoperatively, measurement of femoral component rotation in 90 degrees of knee flexion was conducted in three different positions of the patella: (1) patella reduced, (2) patella dislocated but not everted, and (3) patella dislocated and everted. The femoral component had significantly higher rotation when the patella was reduced compared with a dislocated patella (4.9 ± 2.1 degrees vs. 4.2 ± 2.2 degrees; p = 0.006) and compared with a dislocated and everted patella (4.9 ± 2.1 degrees vs. 4.1 ± 2.3 degrees; p = 0.006). Varus knees (n = 22) demonstrated significantly increased femoral component rotation if the patella was reduced (5.3 ± 2.2 degrees) compared with dislocated patella without eversion (4.7 ± 2.3 degrees; p = 0.037) and with eversion (4.4 ± 2.5 degrees; p = 0.019). As such, the measurement of the mediolateral flexion gap stability with a laterally dislocated patella leads to a statistically significant overestimation of the lateral ligament stability and an underestimation of the external rotation positioning of the femoral component of approximately 1 degree, which is aggravated in varus knees. This is a Level II, prospective consecutive series study.

Для цитирования: Ernstbrunner Lukas, Andronic Octavian, Grubhofer Florian, Jundt-Ecker Michèle, Fucentese Sandro F. The Effect of Patellar Positioning on Femoral Component Rotation when Performing Flexion Gap Balancing Using a Tensioning Device for Total Knee Arthroplasty.. The journal of knee surgery. 2020. DOI: 10.1055/s-0040-1713896.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.