MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1071100720935122

Медицинская библиотека · Foot & ankle international · 2020

Clinical Safety and Efficacy of a Novel Ultrasound-Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries.

Chen Jie, Sharma Akhil, Akoh Craig Chike, Kadakia Rishin, Parekh Selene G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Suture anchors have been used for soft tissue repair in orthopedic surgery for decades. Recently, bioabsorbable suture anchors have increased in popularity and have spurred the introduction of ultrasound-assisted systems. The purpose of our study was to determine the clinical safety and efficacy of a new ultrasound-assisted suture anchor system for foot and ankle procedures.

METHODS

We retrospectively reviewed 50 cases using the ultrasound-assisted suture anchor with at least 24 months of follow-up. We reviewed demographic data including comorbidities, type of procedure, adverse events, and clinical outcomes using the Foot and Ankle Outcome Score (FAOS) and visual analog scale (VAS) score. We divided complications into minor and major, with major complications requiring revision surgery or leading to long-term morbidity. Our primary outcome was complication rates and our secondary outcome was improvement in clinical scores.

RESULTS

The most frequent cases using the anchor included lateral ankle ligament reconstruction (n = 19), insertional Achilles repair (n = 15), lateral ligament reconstruction in conjunction with a total ankle arthroplasty (n = 6), and plantar plate repair (n = 3). There were 5 superficial wound infections that resolved with wound care and/or oral antibiotics. There were 3 major complications (6%): a deep wound infection that required an irrigation and debridement, a deep venous thrombosis, and a recurrence of varus deformity in a patient who underwent a total ankle arthroplasty with lateral ligament reconstruction. Only the varus deformity recurrence case could possibly be directly linked to the suture anchor (2% of all cases). VAS scores improved from 6.0 to 1.2 (P < .001) and FAOS improved from 54.7 to 94.2 (P < .001).

CONCLUSION

This bioabsorbable anchor was a safe device with low failure rates, and it was used for soft tissue repair cases in the foot and ankle with successful clinical outcomes.

LEVEL OF EVIDENCE: Level IV, retrospective case series.

Для цитирования: Chen Jie, Sharma Akhil, Akoh Craig Chike, Kadakia Rishin, Parekh Selene G. Clinical Safety and Efficacy of a Novel Ultrasound-Assisted Bioabsorbable Suture Anchor in Foot and Ankle Surgeries.. Foot & ankle international. 2020. DOI: 10.1177/1071100720935122.