MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/art.10189

Медицинская библиотека · Arthritis and rheumatism · 2002

Defective Fc-dependent processing of immune complexes in patients with systemic lupus erythematosus.

Davies Kevin A, Robson Michael G, Peters A Michael, Norsworthy Peter, Nash Julian T, Walport Mark J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To explore the Fc receptor-dependent handling of immune complexes (ICs) by the fixed mononuclear phagocytic systems (MPS) in patients with systemic lupus erythematosus (SLE).

METHODS

The processing in vivo of soluble model (123)I-hepatitis B/ anti-hepatitis B ICs was studied in 12 healthy subjects and 10 patients with active SLE. ICs that fixed complement poorly were prepared specifically in order to explore Fc receptor-dependent clearance mechanisms. Clearance kinetics and organ uptake were assessed by computer-aided gamma scintigraphy and serial blood sampling.

RESULTS

In both patients and controls, the main site of IC clearance was the liver; only 2-6% of injected ICs were taken up in the spleen. The kinetics of initial IC clearance were similar in both groups, but defective hepatic retention of ICs was demonstrated in patients with SLE. At 1 hour, hepatic activity in patients had fallen to 56% of maximum, compared with 74% in controls (P = 0.0002). Precipitation studies performed on serum samples using staphylococcal protein A-Sepharose indicated that antibody-complexed tracer was released from the liver 20-50 minutes after injection.

CONCLUSION

These results indicate that Fc-mediated clearance of ICs is defective in patients with SLE and suggest that ligation of ICs by Fc receptors is critical for their efficient binding and retention by the fixed MPS in the liver.

Для цитирования: Davies Kevin A, Robson Michael G, Peters A Michael, Norsworthy Peter, Nash Julian T, Walport Mark J. Defective Fc-dependent processing of immune complexes in patients with systemic lupus erythematosus.. Arthritis and rheumatism. 2002. DOI: 10.1002/art.10189.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.