OBJECTIVES

To evaluate whether placing single dental implants either 0.5 or 1.5 mm subcrestally in healed bone crests confers any clinical benefits.

MATERIALS AND

METHODS

Sixty partially edentulous patients requiring two single implant-supported crowns were enrolled in a split-mouth design across six centres. Each site was randomly assigned to receive an implant placed either 0.5 or 1.5 mm subcrestally. Patients were followed up to 10 years post-loading. Outcome measures included crown and implant failures, complications, aesthetics assessed using the Pink Esthetic Score (PES), peri-implant marginal bone level changes, and patient preference.

RESULTS

Eight patients were lost to follow-up. No statistically significant differences were observed between groups regarding implant failures (7 vs. 3; p = 0.125), patients experiencing complications (10 [18.5%] vs. 7 [13%]; p = 0.508), PES (7.66 ± 3.14 vs. 7.46 ± 2.97, p = 0.510). Ten years post-loading, patients in the 0.5 mm group exhibited an average marginal bone loss of 0.38 ± 0.84 mm, while those in the 1.5 mm group showed 0.17 ± 0.45 mm, a difference that was not statistically significant (difference = -0.21 mm; 95% CI -0.47 to 0.04; p = 0.097). No patient preference for implant placement depth was noted. No significant differences in outcomes were found between centres.

CONCLUSIONS

Subcrestal implant placement at either 0.5 or 1.5 mm, when at least 1 mm of surrounding bone is present, seems not to affect the long-term outcomes.

Для цитирования: Esposito Marco, Visconti Riccardo Federico, Gualini Federico, Rigotti Fabio, Mazzarini Cristian, Longhin Diego, Grigoletto Mauro, Giudice Amerigo, Greco Katia, Salina Sergio. Ten-Year Post-Loading Outcomes of Subcrestally Placed Implants With Internal Conical Connections at 0.5 mm Versus 1.5 mm Depth: A Multicentre Within-Person Randomised Controlled Trial.. Clinical oral implants research. 2026. DOI: 10.1111/clr.70135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.