DOI 10.1016/j.ocarto.2023.100356
Cross-sectional reliability and concurrent validity of a quantitative 2-dimensional ultrasound image analysis of effusion and synovial hypertrophy in knee osteoarthritis.
Аннотация
OBJECTIVE
Effusion-synovitis is related to pain and progression in knee osteoarthritis (OA), but current gold standard ultrasound (US) measures are limited to semi-quantitative grading of joint distension or 1-dimensional thickness measures. A novel quantitative 2-dimensional image analysis methodology is applied to US images of effusion-synovitis; reliability and concurrent validity was assessed in patients with knee OA.
METHODS
Cross sectional analysis of US images collected from 51 patients with symptomatic knee OA were processed in ImageJ and segmented in 3DSlicer to produce a binary mask of the supra-patellar synovitis region of interest (ROI). Area measures (mm2) of total synovitis, effusion and hypertrophy components were exported. Intra-rater reliability and test-retest reliability (1-14 days washout) were estimated with intra-class correlation coefficients (ICCs). Concurrent validity was measured by Spearman correlations between quantitative measures and gold standard OMERACT and caliper measurements of synovitis.
RESULTS
Intra-rater reliability for hypertrophy area was estimated at 0.98, 0.99 for effusion area, and 0.99 for total synovitis area. The test-retest reliability for total synovitis area was 0.63 (SEM 87.8 mm2), 0.59 for hypertrophy area (SEM 21.0 mm2), and 0.64 for effusion area (SEM 73.8 mm2). Correlation between total synovitis area and OMERACT grade was 0.84, 0.81 between total synovitis area and effusion-synovitis calipers, and 0.81 between total effusion area and effusion calipers.
CONCLUSION
This new research tool for image analysis demonstrated excellent intra-rater reliability, good concurrent validity, and moderate test-retest reliability. Quantitative 2D US measures of effusion-synovitis and its individual components may enhance the study and management of knee OA.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.