Introduction
Cervical myelopathy is a common disorder of the cervical spine caused by a variety of factors that include trauma, degeneration, neoplasm and infection. 1 , 2
Cervical spondylosis is the most common non-traumatic cause for myelopathy, it is a progressive degenerative disorder in which the diameter of the cervical spinal canal diminishes with degeneration of the cervical disc leading to its collapse, osteophytosis within the vertebral body, hypertrophy of the facets and laminal arches and ossification of the posterior longitudinal ligament (OPLL). 3
Surgical intervention is the optimum treatment option so, various techniques were described for decompression such as discectomy and laminectomy, however, anterior cervical corpectomy remains the mainstay of management. 2
The level of corpectomy is done according to the number of the affected segments. It is thought that the higher the number of levels resected, the higher the failure rate, that’s why the optimal approach for multilevel corpectomy is still unclear. 2 - 4
Reconstruction following corpectomy can be done using bone grafts or synthetic materials, bone grafting includes iliac crest autograft, allograft, or fibular strut graft nevertheless, autograft harvesting has its demerits as donor site pain, infection, fracture, and poor bone quality. Allogenous bone may undergo resorption that results in graft collapse or extrusion. 4 - 6
Taking this in consideration, variable fusion cages have gained acceptance including titanium mesh and polyetheretherketone (PEEK) but lately expandable cages has shown superiority because they can be placed into the defect and precisely adjust to the size of the corpectomy. They can act as a load-sharing device and provide maintenance of cervical lordosis, thus help reducing stress at the screw-plate interface avoiding graft related complications. 5 - 7
Expandable cages can be solitary set up as a stand-alone cage yet, for providing further stability additional plating either anterior or posterior maybe added. Moreover, cages with direct fixation wings have been created in order to make the procedure more simple. 6
Studies have also shown that although expandable systems can serve as solid constructs, restoring normal alignment and height of the spine, the rates of complication and re-operation, especially in tumor patients, remain high. 7
In this study, we review using expandable cages for anterior cervical corpectomy and reconstruction regarding their efficacy, post-operative outcomes and possible complications.
Methods
We performed this study in adherence to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. 8
Search Strategy and Study Selection
We conducted a systematic search by title and abstract on the following databases: Medline (through PubMed), Scopus, Web of Science, Cochrane and Embase up until 22 nd of May 2023. We used the MeSH database to retrieve the synonyms of our search strategy, and the terms were combined using “OR” and “AND” Boolean operators, in accordance with the Cochrane Handbook for Systematic Reviews (Chapter 4.4.4). 9 The terms were as follows: ((“Anterior corpectomy” OR “Anterior cervical discectomy and corpectomy” OR ACDC OR “Cervical corpectomy” OR “Decompressive corpectomy” OR “Anterior decompression and fusion” OR ADF OR “Anterior cervical decompression and fusion with corpectomy” OR ACDF OR “Anterior cervical vertebrectomy” OR “Anterior cervical osteotomy and corpectomy” OR “Anterior cervical resection and fusion” OR ACRF OR “Anterior cervical spine surgery with corpectomy” AND “Myelopathy OR Spondylosis OR Spondylolisthesis OR Spondylolysis OR “Spinal Osteophytoses” OR “Spinal Osteophytosis” OR “Ossification of Posterior Longitudinal Ligament” OR “Intervertebral Disc Degenerations”). Following the removal of duplicates, a team of 7 authors screened the retrieved studies based on our predefined eligibility criteria using titles and abstracts. Additionally, we conducted a manual search by reviewing the references of the included articles, and literature reviews for possible relevant studies. Subsequently, the list of included studies was subjected to further scrutiny by two authors. Studies deemed relevant and any conflicts were subjected to full-text screening. The detailed search process and the selection of studies are elaborated in the accompanying PRISMA diagram ( Figure 1 ).

Eligibility Criteria
We incorporated studies that assessed the anterior cervical corpectomy with an expandable cage in individuals with myelopathy. There were no restrictions placed on language or study type. To ensure the quality and relevance of the included studies, we excluded duplicate publications, reviews, letters to editors, book chapters, animal and laboratory studies and in vitro investigations.
Data Extraction
Four authors undertook the task of extracting data from the included studies, entering the collected information into an Excel spreadsheet. To guarantee data accuracy and consistency, fifth author meticulously reviewed the completed extraction sheet, reconciled any discrepancies, and validated the precision of the data.
The data extraction encompassed several key elements, starting with study characteristics such as the first author’s name, publication year, study design and duration of the disease under investigation. Population characteristics, including sample size, gender distribution, age demographics, interventions administered, Indications for surgery, complications (dysphagia, epidural hematoma, neck pain, transient vocal cord paralysis, transient neurological worsening, and hardware-related issues) and efficacy outcomes. Furthermore, when applicable data on the used cage, different scores such as modified Japanese orthopaedic score (mJOA) and stability rate were available we gathered it also.
For the quantitative analysis, the same authors independently extracted related information; the reported pain scales (before, during and after the surgery), Nurick score, mean hospital stay, mean blood loss, mean surgical time, mean kyphosis and cervical lordosis angle, successful fusion percentage, C2–C7 Cobb’s angle pre and post operation and Mean duration of follow-up.
The data of interest were collected in the form of mean and standard deviation or number and total. Data reported using different formats were converted into mean and standard deviation values using the website developed by McGrath et al which is an online tool used to facilitate the estimation of sample mean and standard deviation, ensuring consistency in the data presentation and analysis. 10
Critical Appraisal Tool and Risk of Bias Assessment
Two authors conducted an assessment of the risk of bias in the included studies. The National Institute of Health (NIH) Quality Assessment Tools for Observational Cohort and Cross-sectional Studies and case series studies were employed for this purpose. 11
The assessment involved rating studies on a scale of 0 for poor (0-4 out of 14 questions), i for fair (5-10 out of 14 questions), and ii for good (11-14 out of 14 questions) in case of the first tool while in the second tool it addressed nine questions addressing the study objective or question, population, intervention, outcomes, follow up, statistical method and result reporting. In cases where certain questions were not applicable (NA) or not reported (NR), these designations were used accordingly. For case-control studies, the Newcastle-Ottawa Scale (NOS) was utilized. 12 This scale assigns ratings ranging from 0 to 9, with studies scoring within the range of 0-2 being categorized as poor quality, those scoring 3-5 as fair quality, and those scoring 6-9 as good/high quality. For case-report studies, the Jonna Briggs Institute (JBI) critical appraisal tool, which consists of eight questions that evaluate the methodological quality of a study and determine the extent to which a study has addressed the possibility of bias in its design, conduct, and analysis was used. 13
In instances where differences in assessment arose between the two authors, a third author was involved to mediate and resolve any disagreements, ensuring the integrity and consistency of the risk of bias evaluation process.
Data Analysis
Our meta-analysis was conducted using the “OpenMetaAnalyst” software and meta-package of the R software (R version 4.1.0), encompassing a systematic approach to extract and analyze data from the selected studies. 14 In the initial analysis, we focused on mean values and measures of reported scores such as mJOA and Nurick before and after the treatments at different timing when available. For this analysis, we conducted a pooling of mean values for each score separately. The mean difference also has been calculated for some analysis such as pre and post operation angel changes. Also, pooling for the proportions and risk ratio analysis have been conducted. We assessed the heterogeneity using the I 2 and chi-squared tests and applied the random effect model. Heterogeneity was considered substantial when I 2 was more than 50% at a P -value <0.05. Funnel plot wasn’t made due to the low number of studies (<10) in each subanalysis.
Results
Search Results
Our search process retrieved 5796 records. We identified and removed 2861 duplicates using EndNote software. 2935 records were screened by title and abstract using preformed excel sheet, 2753 were excluded for not matching our eligibility criteria. We identified and retrieved 182 articles for full text screening, 170 articles were excluded; 162 were considered not relevant, 6 reviews, one editorial and an abstract of an already included study. 12 studies were qualified from the screening process while 18 studies were identified by manually searching the databases and references of the related studies; the net result of the included studies is 30 studies. Figure 1 illustrates the PRISMA flow diagram.
Characteristics of the Included Studies
We included 30 studies in the review, 1 - 7 , 15 - 36 of which 22 were eligible for meta-analysis. The summary of the included studies is illustrated in Table 1 .
Table 1.
Summary of the Included Studies.
| Study ID | Study design | Disease or Patients | Intervention | Study arms | Duration | Primary outcomes |
| M. payer, 2006 | Prospective observational study | Twenty consecutive patients with: 1. Spondylotic myelopathy in 12 patients. 2. Traumatic cervical fracture in 3 patients 3. Vertebral metastases in 3 patients 4. Anterior cervical meningioma in one patient 5. Chondrosarcoma in one Patient | Anterior cervical corpectomy with subsequent reconstruction using expandable titanium cage and anterior cervical plate and/or posterior lateral mass or pedicle screw fixation | Single arm | _ | - Surgery time - Blood loss - Neurological Deficit - Neck pain - Regional lordosis - Hardware failure - Postoperative complications |
| Sastry et Al., 2021 | Retrospective cohort study | 20 patients with multilevel cervical spondylotic myelopathy | Hybrid anterior cervical corpectomy and discectomy with reconstruction using expandable cage with anterior plating | Single arm | Between June 2015 and December 2018 | -Incidence of and reason for subsequent posterior cervical surgery - Incidence of and reason for subsequent anterior cervical surgery - Progressive symptomatic myelopathy -Radiographic hardware failure - A net reduction of pre-operative kyphosis |
| Hartmann et Al., 2017 | Retrospective study | 45 patients total: 1. 32 with degenerative spinal canal stenosis with myelopathy 2. 8 patients with metastatic lesions 3. 3 patients with infections of cervical spondylodiscitis 4. 2 patients with vertebral fractures | Treated by an anterior cervical corpectomy and graft reconstruction and plating with 4 patients treated by expandable cervical cages and plating | Single arm | Between 2011 and 2014 | - Surgery time - Blood loss - Blood transfusion - Postoperative complications |
| Woiciechowsky, 2005 | Retrospective study | 20 patients with degenerative cervical spinal canal stenosis | Treated with anterior corpectomy followed by the placement of expandable titanium cage with anterior plate or winged expandable cage | Single arm | From 1998 to 2002 | - Solid arthrodesis. - Cervical lordosis. - Odom criteria. - Complications. |
| Gill et. Al., 2021 | Retrospective study | 120 patients of cervical spondylotic myelopathy who underwent surgical decompression | 59 patients underwent surgical decompression by an anterior approach and the remaining 61 patients by the posterior approach. Out of the 59 patients operated by the anterior approach, 30 (50.85%) underwent anterior cervical discectomy and fusion (ACDF); the remaining 29 (49.15%) underwent anterior cervical corpectomy and fusion with reconstruction using expandable cage with plating and screw fixation or Paramesh cage | Three Arms | from June 2015 to December 2019 | - Neurological outcomes (Nurick - modified Japanese orthopedic association (mJOA) - Canal diameter - Cross-sectional area |
| Nigro et al., 2017 | Prospective study | 34 patients with cervical spondylosis. | Anterior cervical corpectomy and reconstruction using winged titanium expandable cage. | Single arm | From May 2011 to May 2013 | - Nurick’s scale - Post-operative complications - Subsidence |
| Zairi et al., 2012 | Retrospective study | Spondylotic myelopathy | Anterior cervical corpectomy and reconstruction using expandable titanium cage and anterior plating | Single arm | Between 2005 and 2008 | - Surgery time - Blood loss - Hospital stays - Visual analogue scale (VAS) - mJOA - Kyphosis -Fusion |
| Perrini et al., 2015 | Retrospective study | Spondylotic myelopathy | Anterior cervical corpectomy and reconstruction using expandable cage with anterior plating or with iliac crest auto-graft and plating | 2 arms: 1 .Expandable cylindrical cage (ECC) group 2. Iliac crest auto graft group | 12-year period (January 2002–December 2013). | - Nurick scale - mJOA - Hospital stays - Complications - Cobb angle - Subsidence - Fusion rate |
| Waschke et al., 2013 | Retrospective study | 1. Degenerative spondylosis 28 (58.3 %) 2. Cervical disc disease with stenosis 9 (18.7 %) 3. Tumor 7 (14.6 %) 4. Spondylodiscitis/osteomyelitis 2 (4.2 %) 5. Ossified posterior longitudinal ligament 2 (4.2 %) | Anterior cervical corpectomy and fusion with reconstruction using expandable cervical titanium cages and anterior plating | Single arm | Between 2005 and 2011 | - Successful fusion - VAS - Cobb angle. |
| Tarantino et al., 2016 | Prospective | Cervical spondylosis | Anterior cervical corpectomy followed by the insertion of a winged expandable cage, a left-sided standard anterior cervical approach was used in all the cases except in one case in which manubriotomy was done to obtain access to T1 | Single arm | From May 2011 to May 2013 | - Nurick scale - Subsidence - Postoperative complications |
| Tohamy et al., 2022 | Retrospective study | Spinal canal stenosis with or without cervical spondylosis affecting the levels C3/4 to C7/T1 | Anterior cervical corpectomy and fusion was performed through a standard anterior cervical approach by microscopy-assisted dissection with a cervical expandable titanium cage insertion | Single arm | Between 2014 and 2016 | - VAS - 10 Neck disability index (ND) - Fusion - Subsidence - Global cervical lordosis |
| Pojskic et al., 2020 | Retrospective study | 1. Spinal canal stenosis with myelopathy (46 or 53.5%) 2. Metastasis (24 or 27.9%) 3. Spondylodiscitis (12 or 14%) 4. Fracture (4 or 4.6%). | Anterior corpectomy and reconstruction with expandable cage: 1. Standalone in 13 patients 2. 34 with anterior plate 3. 360 fusion in 39 patients | Single arm | From January 2012 to December 2019 | - VAS - Nurick score - Fusion - Subsidence - C2-C7 angle |
| KÖNIG et al., 2014 | Retrospective study | 32 patients | Anterior cervical corpectomy and reconstruction using: 1. Winged distractible titanium cages (n=6) 2. PEEK cages (n=19) 3. Iliac crest bone graft (n=7) | Three arms | Between January 2010 and August 2012. | -mJOA |
| Seervi et al., 2023 | Retrospective study | 100 patients total: 1. 53 patients with traumatic cervical spine disease 2. 34 patients with cervical degenerative spine disease 3. 6 patients of cervical Pott’s spine 4. 6 patients of ossified posterior longitudinal ligament 5. 1 patient of multiple myeloma | Anterior Cervical Corpectomy with Fusion using stand-alone cage and Expandable Cage with Anterior Cervical Plating | Two arms: 1. 60 patients used expandable cages alone 2. 40 patients used expandable cages with an anterior cervical plate | From January 2019 to December 2021 | - Cobb angle - Nurick scale - intraoperative - postoperative complications |
| Cabraja et al., 2010 | Retrospective study | 48 patients with cervical myelopathy. | 1. Anterior corpectomy with expandable cage placement and anterior plating 2. Laminectomy with lateral mass screws | Single arm | Between 1998 and 2008 | - Cobb angle - Stability - Solid arthrodesis |
| Brenke et al., 2016 | Prospective study | 1. Degenerative disease in 28 patients 2. Traumatic causes in 4 patients 3. Neoplasm in 12 patients 4. Infectious disease in 6 patients | Anterior cervical corpectomy and replacement with expandable titanium cage and anterior plating alone in 34 patients or with or pedicle screw fixation in 16 patients | Single arm | From 2010 to 2015 | - Complications - Segmental height - Regional angulation. - Coronal alignment in relation to the upper cervical vertebra |
| M. Cabraja et al., 2010 | Retrospective study | 1. Spondylosis in 20 cases 2. Tumor in 8 cases 3. Degenerative kyphosis in 6 cases 4. Infections in 4 cases 5. Ossification of the posterior longitudinal ligament in 3 cases 6. Spondylolisthesis in 2 cases 7. Epidural bleeding in 1 case | 1. Cervical corpectomy and reconstruction with expandable cervical cage plus ventral plating in 16 patients 2. Cervical winged expandable cage in 28 cases | Two arms | From 1998 to 2005. | - Cervical lordosis - The angle between the adjacent vertebral bodies - Fusion rates - Stability - neurological outcome - Complications. |
| Zhang et al., 2005 | Retrospective | 10 patients: 1. Cervical fractures in 5 patients 2. Plasmacytoma in 1 patient 3. Bacterial osteomyelitis in 1 patient 4. Severe kyphotic deformity in 3 patients | Anterior cervical corpectomy and reconstruction using expandable cage with anterior plating with or without posterior fixation | Single arm | From 2001 to 2003. | - Functional outcome - Complications - Cobb angle - Subsidence |
| A. Waschke et al., 2013 | Prospective observational clinical study | Nine patients with Vertebral fracture because of: 1. tumor infiltration in 6 cases 2. Osteoporosis 3 cases | Anterior cervical corpectomy and reconstruction using expandable titanium cage and additional anterior plating | Single arm | Between January 2009 and October 2011 | - Visual analogue scale (VAS) - Nurick scale - Cobb angle - Cervical lordosis - Subsidence ratio - The 36-Item Short Form Health Survey questionnaire (SF-36) |
| Burkett et al. 2012 | Retrospective case series | 1. 12 patients with spondylosis 2. 11 with a traumatic fracture or ligamentous injury 3. 2 with osteomyelitis 4. 1 with a deformity 5. 1 developmental condition 6. 1 hardware failure 7. 1 tumor. | Anterior cervical corpectomy and reconstruction using an expandable titanium cage and anterior plating with or without posterior plating | Single arm | Between September 2007 and August 2010. | - Fusion - Complications |
| Pahwa et al. 2020 | Prospective cohort study | Patients with traumatic and degenerative cervical spondylosis. | Anterior cervical corpectomy and reconstruction either using winged expandable cage or with non-expandable cage | Two arms: - expandable cage (10 patients) - non-expandable cage (10 patients) | _ | - Intraoperative time - Postoperative fusion - Complications |
| Doria et al., 2017 | Retrospective cohort | Multi-level symptomatic degenerative disc disease, disc herniation, or stenosis of the cervical spine with clinical criteria of myelopathy and radiological criteria of cord compression | All patients recived anterior cervical corpectomy and reconstruction using: 1. strut iliac bone graft and anterior plate in 49 patients 2. Titanium expanding cage and anterior plating in 26 patients 3. Titanium mesh cage with autologous bone graft and anterior plating in 39 patients | Single arm | Between July 2009 to December 2011 | - A score based on the criteria of neck pain, depending on drugs and ability to return to daily activities - Visual Analog Scale - Nurick's score - Fusion rate - Complications - Overall quality of life improvement |
| Weber et al., 2017 | Retrospective cohort | Patients with cervical spondylotic myelopathy | Anterior cervical corpectomy and reconstruction using 1. Fibula allograft and anterior plating (N=32) 2. Titanium Mesh Cage and anterior plating (N=18) 3. Titanium Expandable Cage and anterior plating (N=16) 4. Carbon Fiber Cage and anterior plating (N=9) | Four arms | Between 2005 and 2009 | Subsidence and revision rates |
| Yusupov et al., 2020 | Retrospective cohort | 1. Degenerative stenosis 21 (53%) 2. Traumatic injury of the spine 4 (10%) 3. Neoplastic compression of the spine 12 (30%) 4. Infectious spondylodiscitis 3 (7%) | Anchored expandable titanium cages | Single arm | Between October 2011 to April 2017 | - McCormick classification - Odom Score - Cobb and β-angles - Postoperative position - Fusion rate - Subsidence rate |
| Alfieri et al., 2011 | Case series | Patients with Spinal metastatic tumor resection. | Anterior cervical corpectomy and reconstruction using: 1. Stand-alone expandable cage in 2 patients 2. Winged expandable cage in 4 patients | Single arm | Between June 2004 and January 2006 | - VAS - complications |
| Auguste et al., 2006 | Retrospective cohort | 1. Spondylotic myelopathy in 16 patients 2. Osteomyelitis in 2 patients 3. Fracture in 2 patients 4. Tumor metastasis in 1 patient 5. Severe stenosis in one patient | Anterior cervical corpectomy Followed by insertion of Expandable cervical cage with anterior plate with or without posterior fixation | Single arm | Between January 2003 and May 2004 | - VAS - Nurick's score - Stability - Fusion rate - Kyphotic angle - complications |
| Omeis et al., 2010 | Retrospective cohort | Patients with cervical spine metastatic disease | Multilevel corpectomies followed by insertion of an Expandable cervical cage with anterior and posterior fixation. | Single arm | From August 2006 to May 2008 | - Visual analog scale (VAS) - Nurick grade - Frankel grade - American Spinal Injuries Association (ASIA) grade - Ranawat grade |
| Pape et al., 2011 | Retrospective cohort | 1. Degenerative pathologies (n=18) 2. Infection (n=4), tumor (n=6) 3. Trauma (n=1) | Anterior cervical corpectomy followed by insertion of winged expandable cage | Single arm | Between April 2006 and November 2010 | - NDI (neck disability index) - Clinical improvement - Complications |
| Ezzati et al., 2011 | Case series | 1. Degenerative spinal canal stenosis in 31 patients 2. Metastatic lesions in 7 patients 3. Spondylodiscitis in 2 cases | Anterior cervical corpectomy and reconstruction using stand-alone expandable cage | Single arm | Between July 2008 and December 2010 | - The mean postoperative obtained height - The mean postoperative sagittal correction - The mean operative time and complications. |
| Chiriac et al., 2016 | Case report | Progressive cervical myelopathy syndrome | Anterior cervical corpectomy and reconstruction using expandable cage with an anterior plate | _ | _ | mJOA |
We used New castle-Ottawa scale (NOS) for observational studies to assess the risk of bias in 8 studies; two studies was scaled good, 5 studies was scaled fair while one study was scaled poor quality ( Supplement Table 1 ). According to Quality Assessment Tool for Case Series Studies (NIH), four of five studies was of good quality while one study was of fair quality ( Supplement Table 2 ). We used Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies (NIH) to assess the quality of 16 studies; four studies were of good quality while twelve was of fair quality ( Supplement Table 3 ). In one case report study, we used JBI Critical Appraisal Checklist for Case Reports to assess quality and the study was of good quality ( Supplement Table 4 ).
Efficacy and Safety Outcomes
Cobb Angle
Five studies involving 296 participants indicated statistically significant improvement of Cobb’s angle after cervical corpectomy compared to pre-operative measurement. The mean difference was 5.29°, 95% CI = [2.87, 7.71], with substantial heterogeneity (I 2 = 70%). Subgroup analysis showed a statistically significant improvement in Cobb’s angle compared to pre-operative measurement using an expandable cage with anterior plating (MD = 5.95, 95% CI = [2.78, 9.13]), stand-alone expandable cage (MD = 3.52, 95% CI = [1.24, 5.80]) and stand-alone anchored expandable cage or with anterior or posterior plating (MD = 9.20, 95% CI = [2.21, 16.19]), while the group using expandable cage which is either Stand-alone, with anterior plate, with posterior plate or with anterior and posterior plate showed statistically insignificant decrease in the Cobb’s angle (MD = −1.80, 95% CI = [-11.92, 8.32]). The heterogeneity between the studies in the expandable cage with anterior plating group was substantial (i 2 = 75%), see Figure 2 .

Nurick’s Score
Six studies involving 281 patients indicated improvement of Nuruick’s score -decrease- throughout the follow up. The overall mean dropped from 2.71 (95% CI = [2.41, 3.02]) pre-operative to 2.06 (95% CI = [1.78, 2.34]) at 6 months and 1.78 (95% CI = [1.0, 2.75]) post operatively (at the end of follow up). The heterogeneity between studies was considerable pre and post operatively – (i 2 = 85% and 95% respectively) - while it was moderate at 6 months (i 2 = 45%). In Seervi et al, 2023 stand-alone expandable cage group showed improvement of the mean Nurick score by 0.42 points while in the group using expandable cage with anterior plate it improved by 0.65 points at 6 months. In Perrini et al, 2016 using extendable cage with anterior plate it improved by one point while in Tarantino et al, 2016 using Winged expandable cage it improved by 1.41 points at 24 months. Auguste et al, 2007 which used stand-alone anchored expandable cage showed improvement by one point post operatively compared to pre-operative measurements, see Figure 3 .

Modified Japanese Orthopaedic Scale (mJOA)
Five studies including 107 patients indicated improvement of mJOA throughout the follow up. The overall mean increased from 11.96 (95% CI = [10.20, 13.71]) preoperatively to 14.53 (95% CI = [12.28, 16.79]) at six months, 15.03 (95% CI = [14.32, 15.73]) at 12 months and 16.04 (95% CI = [15.18, 16.90]) at 24 months. The heterogeneity between the studies were considerable pre-operatively and at 6 months of follow up while it was substantial at 12 months of follow up. In Perrini et al, 2015, Zairi et al, 2012 and Cabraja et al, 2010 which used expandable cage with anterior plate the mean improvement at the end of follow up was 2.1, 3.19 and 2.7 respectively while in Koing et al, 2014 which used winged expandable cage it was 2.5, see Figure 4 .

Angels
Five studies including 133 patient showed statistically significant improvement of the angels after cervical corpectomy compared to pre-operative measurements. The mean difference was 5.28°, 95% CI = [3.28, 7.28] with no heterogeneity (i 2 = 0%). In the group using stand-alone expandable cage the mean difference was 4°, 95%CI = [0.13, 7.87] while in the group using expandable cage with anterior plate the mean difference was 6.28°, 95%CI = [2.98, 10.65] and in the group using expandable cage with anterior plating with or without posterior plating it was 5.45° 95%CI = [1.19, 9.70] and all showed significant difference compared to pre-operative measurements. The studies in the group using expandable cage with anterior plate were homogenous (i 2 = 0%) while in the group using expandable cage with anterior plating with or without posterior plating the heterogeneity was moderate (i 2 = 48%) ( Supplement Figure 1 ).
Stability Rate
The outcome was present in 7 studies, the overall stability rate was 0.94, 95%CI = [0.91, 0.98] and the heterogeneity between studies was might not be important (i 2 = 8.14%). Sub group analysis showed that the stability rate was 0.95 (95% CI = [0.88, 1.03]) in the group using Expandable cage with anterior plating with or without posterior plating, 0.94 (95% CI [0.86, 1.01]) in the group using expandable cage with anterior plating, 0.91 (95% CI = [0.82, 1.00]) in the group using winged expandable cage and 0.83 (95% CI = [0.41, 1.26]) in the group using stand-alone cage. The heterogeneity between studies in the group using expandable cage with anterior plating was substantial (i 2 = 64.67%), while in the groups using winged expandable cage and Expandable cage with anterior plating with or without posterior plating the studies were homogenous (i 2 = 0%), see Figure 5 .

Successful Fusion
This outcome was present in 14 studies, the overall fusion rate was 0.94 with 95% CI = [0.91, 0.97] and the heterogeneity among the studies was moderate (i 2 = 54.79%). Subgrouping showed that fusion rate was 0.98 (95% CI = [0.95, 1.01]) in the group using expandable cage with anterior plating with or without posterior plating, 0.94 (95% CI = [0.89, 0.99]) in the group using expandable cage with anterior plating, 0.92 (95% CI = [0.85, 1.00]) in the group using winged expandable cage, 0.78 (95% CI = [0.64, 0.92]) in the group using winged expandable cage with posterior plating, PEEK or iliac bone graft and 0.89 (95% CI = [0.69, 1.09]) in the group using Stand-alone expandable cage. The studies in the group using expandable cage with anterior plating with or without posterior plating and winged expandable cage were homogenous (i 2 = 0%), in the group using expandable cage with anterior plating the heterogeneity was not moderate (i 2 = 57.36%) while in the group using stand-alone expandable cage it was considerable (i 2 = 91.81%), see Figure 6 .

Dysphagia
The outcome was reported in 11 studies, the overall incidence was 0.16 with 95% CI = [0.08, 0.24] and the heterogeneity between the studies was considerable (i 2 = 89.4%). Subgroup analysis showed that the incidence was 0.34 (95% CI = [-0.24, 0.93]) in the group using stand-alone expandable cage, 0.20 (95% CI = [0.02, 0.38]) in the group using expandable cage with anterior plating, 0.08 (95% CI = [-0.00, 0.16]) in the group using expandable cage with anterior plating with or without posterior plating, 0.06 (95% CI = [-0.02, 0.14) in the group using winged expandable cage, 0.09 (95% CI = [0.03, 0.15]) in the group using expandable cage which is either Stand-alone, with anterior plate, with posterior plate or with anterior and posterior plate and 0.07 (95% CI = [-0.01, 0.16]) in the group using stand-alone anchored expandable cage or with anterior or posterior plate.
The heterogeneity between studies in the groups using expandable cage with anterior plating and stand-alone cage was considerable (i 2 = 93.12% and 97.69% respectively) while the studies in the group using expandable cage with anterior plating with or without posterior plating were homogenous (i 2 = 0%) ( Supplement Figure 2 ).
Fractures
The outcome was present in three studies, the overall incidence was 0.06 with 95% CI = [0.01, 0.10] and the heterogeneity between the studies was not important (i 2 = 0%). Subgroup analysis showed that the incidence was 0.03 (95% CI = [−0.03, 0.09]) in the group using winged expandable cage, 0.04 (95% CI = [−0.04, 0.11) in the group using expandable cage with anterior plating and 0.10 (95%CI = [0.04, 0.17]) in the group using expandable cage which is either Stand-alone, with anterior plate, with posterior plate or with anterior and posterior plate ( Supplement Figure 3 ).
Hardware Related Issues
The outcome was present in 8 studies, the overall incidence was 0.09 with 95% CI = [0.04, 0.15] and the heterogeneity was substantial (i 2 = 65.31%). Subgroup analysis showed that the incidence was 0.12 (95% CI = [−0.04, 0.28]) in the group using expandable cage with anterior plating with or without posterior plating, 0.0.07 (95% CI = [0.02, 0.13]) in the group using expandable cage with anterior plating , 0.03 (95% CI = [-0.03, 0.09]) in the group using winged expandable cage and 0.015 (95% CI = [0.08, 0.23]) in the group using expandable cage which is either Stand-alone, with anterior plate, with posterior plate or with anterior and posterior plate. The studies in the group using expandable cage with anterior plating was homogenous (i 2 = 0%), while in the group using expandable cage with anterior plating with or without posterior plating the heterogeneity was substantial (i 2 = 86.21%) ( Supplement Figure 4 ).
Transient Neurological Worsening
The outcome was present in 5 studies, the overall incidence was 0.06 with 95% CI = [0.02, 0.11] and the heterogeneity between studies may be moderate (i 2 = 43.71%). Subgroup analysis showed that the incidence was 0.05 (95% CI = [−0.03, 0.12]) in the group using Expandable cage with anterior plating with or without posterior plating, 0.04 (95% CI = [−0.04, 0.11]) in the group using expandable cage with anterior plating, 0.03 (95% CI = [-0.03, 0.09]) in the group using winged expandable cage and 0.15 (95% CI = [0.08, 0.23]) in the group using Expandable cage which is either Stand-alone, with anterior plate, with posterior plate or with anterior and posterior plate ( Supplement Figure 5 ).
Hardware Failure Requiring Additional Surgery
The outcome was present in 10 studies, the overall incidence was 0.08 with 95% CI = [0.04, 0.12] and the heterogeneity between the studies was substantial (i 2 = 60%). Subgrouping showed that the incidence was 0.05 (95% CI = [0.01, 0.10]) in the group using expandable cage with anterior plating, 0.05 (95% CI = [−0.02, 0.12]) in the group using winged expandable cage, 0.03 (95% CI = [−0.03, 0.09]) in the group using winged expandable cage with posterior plating or PEEK cage or iliac bone graft, 0.17 (95% CI = [0.07, 0.26]) in the group using stand-alone expandable cage, 0.24 (95% CI = [0.12, 0.36]) in the group using expandable cage with anterior plating with or without posterior plating, 0.15 (95% CI = [0.08, 0.23]) in the group using expandable cage which is either stand alone, with anterior plating, posterior plating or with anterior or posterior plating and 0.02 (95% CI = [−0.02, 0.07]) in the group using stand-alone anchored expandable cage or with anterior or posterior plating. The studies in the group using expandable cage with anterior plating was homogenous (i 2 = 0%) while in the group using winged expandable cages it was not important (i 2 = 29.56%) ( Supplement Figure 6 ).
Visual Analogue Scale (VAS)
VAS was reported in eight of the included studies and was generally decreased at the end of follow up except in Payer, 2006 in both traumatic fracture group and chondrosarcoma group it increased, see Table 2 .
Table 2.
Visual Analogue Scale (VAS).
| Study ID | Group (n) | Cage used | VAS | |||||
| Pre-op | 1 month | 3 months | 6 months | 12 months | Number | |||
| Payer, 2006 | Spondylotic myelopathy group (12) | Distractible titanium cage with anterior cervical plate and/or posterior lateral mass or pedicle screw fixation | 4.6 | - | 3.4 | 2.9 | 2.8 | 12 |
| Traumatic fracture group (3) | 1 | - | 3 | 2.7 | 2.7 | 3 | ||
| Cervical metastasis group (3) | 5.3 | - | 2.3 | 2.3 | 2.7 | 3 | ||
| Meningioma group (1) | 4 | - | 4 | 3 | 1 | 1 | ||
| Chondrosarcoma group (1) | 0 | - | 3 | 3 | 2 | 1 | ||
| Zairi et al., 2012 | Cervical spondylotic myelopathy (26) | Expandable titanium cage with anterior plate | Mean and SD: 4.2 (13) (range:0-10) | - | 2.1 (13) (range: 0-10) | 1.7 (9.1) (range:0-7) | 1.8 (9.1) (range:0-7) | 26 |
| Waschke et al., 2013 | One group (48) | Expandable titanium cage and an anterior cervical plate | 6.1 | 5.8 (6 weeks at discharge) | 3.2 | 48 | ||
| Pojskic et al., 2020 | Cervical spinal canal stenosis (46) | Expandable titanium cage either stand-alone (13) or with an anterior plate (34) or with a posterior plate (28) or with an anterior and posterior plate (11) | 7.5 | 3 (only mentioned that post-op follow-up up done at 3.12.24 months) | 46 | |||
| Spondylodiscitis (12) | 9.7 | 2.6 (only mentioned that post-op follow-up up done at 3.12.24 months) | 12 | |||||
| Metastases (24) | 6.5 | 2.5 (only mentioned that post-op follow-up up done at 3.12.24 months) | 24 | |||||
| Fracture (4) | 8 | 2.8 (only mentioned that post-op follow-up up done at 3.12.24 months) | 4 | |||||
| Cabraja et al., 2010 | One group (24) | Expandable cage with anterior plating (24) | 4.8 (1.2) | At 12 months 3.3(1) and at 33 months was 3.3(1.1) | 24 | |||
| Tohamy et al., 2022 | One group (31) | Expandable titanium cage (stand-alone) | 5.7 (1.08) | Post-op 6.3 (1.04) | At the end of follow-up 2 (1.11) | 31 | ||
| Alfieri et al., 2011 | One group (6) | 2 Winged expandable cages 4 Stand-alone expandable cage | 7 | post op 3.6 follow-up period mean 9.6 range 6-18 | 6 | |||
| Auguste et al., 2006 | One group (18) | Expandable cervical cage with anterior plate with or without posterior plate | 7.3 (1.5) | post op 2.6 (1.5) | 18 |
The mean duration of follow up was minimally 6 months in Pahwa et al, 2020 and maximally 77.5 in Perrini et al, 2015 ( Supplement Table 5 ) while the mean hospital stay was at least 2.6 in Sastry et al, 2021 and maximally 10.6 in Pojskic et al, 2020 ( Supplement Table 6 ). The mean surgical time was reported in eight of the included studies and it was least in Pahwa et al, 2020 in the group using winged expandable cage while it was most in Burkett et al, 2012 using expandable titanium cage with anterior and/or posterior fixation ( Supplement Table 7 ).
Mean blood loss was reported in 6 of the included studies and it was least in Sastry et al, 2021 using expandable cage with anterior plating while it was most in Payer, 2006 in the group underwent 3 level corpectomy ( Supplement Table 8 ). In four studies which reported epidural hematoma only five patients were involved ( Supplement Table 9 ) while neck pain was reported in 5 studies and involved 22 patients out of 139 patients, 14 of them was in Waschke et al, 2013 ( Supplement Table 10 ).
Subsidence was reported in 11 of the included studies and included 66 out of 454 patients. In Seervi et al, 2023 only 2 patients in the expandable cage with anterior plate group had subsidence while in stand-alone cage group 13 patients had subsidence and in KÖNIG et al, 2014 subsidence didn’t occur in the winged expandable cage group while 6 patients in the PEEK group had subsidence ( Supplement Table 11 ).
Discussion
This meta-analysis synthesized data from 30 studies investigating the clinical outcomes of anterior cervical corpectomy using expandable cages. While the use of expandable cages generally led to favourable outcomes in terms of fusion rates, neurological improvement, and pain reduction, significant variability in outcomes across different cage designs and surgical techniques demands further attention.
Cobb Angle Improvement
The improvement in Cobb’s angle across studies was notable, with an overall mean difference of 5.29°, demonstrating the effectiveness of expandable cages in restoring sagittal alignment. However, the substantial heterogeneity in some subgroups, particularly in the expandable cages without anterior plating (MD = −1.80, 95% CI = [−11.92, 8.32], I 2 = 75%), suggests that the lack of additional plating may compromise stability and lead to less favourable outcomes. In contrast, the group using expandable cages with anterior plating showed significant improvement (MD = 5.95, 95% CI = [2.78, 9.13]), highlighting the clinical benefit of anterior plating in maintaining alignment post-operatively.
Given the variability in results, particularly the insignificant change in Cobb’s angle in some subgroups, it is important to consider patient-specific factors and surgical techniques when selecting between stand-alone and plated cages. The substantial heterogeneity suggests that factors such as pre-operative spinal alignment, the extent of corpectomy, and surgical expertise may influence outcomes.
Nurick’s Score Improvement
The improvement in Nurick’s score from 2.71 pre-operatively to 1.78 post-operatively was significant, but the high heterogeneity (I 2 = 85% pre-operatively and 95% post-operatively) indicates variability in patient recovery. The subgroup using stand-alone expandable cages showed a smaller improvement (0.42 points), compared to the cages with anterior plating (0.65 points). This suggests that the additional support provided by anterior plating may contribute to better neurological recovery.
The high heterogeneity across studies could be explained by differences in follow-up duration, surgical techniques, or patient characteristics. Addressing these factors in future research will help to refine the use of expandable cages in different clinical scenarios.
Modified Japanese Orthopaedic Association (mJOA) Scores
The mJOA scores improved consistently from 11.96 pre-operatively to 16.04 at 24 months, reinforcing the effectiveness of expandable cages in enhancing neurological function. However, significant heterogeneity was observed pre-operatively and at 6 months of follow-up, reflecting variability in patient response to surgery. The group using expandable cages with anterior plating showed slightly better outcomes (mean improvements ranging from 2.1 to 3.19 points), further supporting the advantage of additional anterior column support.
Given the variability in improvement, clinicians should consider the use of anterior plating, particularly in cases where greater neurological recovery is anticipated. The heterogeneity in outcomes could be due to differences in the extent of myelopathy or surgical technique, warranting further investigation.
Impact of Demographic and Comorbidities
The heterogeneity observed in Nurick’s and mJOA scores across included patient groups subjected to varied demographic factors eg, age, comorbidities, and pre-op myelopathy severity. These two techniques stand-alone and cage plate structures pre-op and post-operative outcomes are differed. Elias et al (2024) also determined in its systematic review and meta-analysis that age of the patient played significant role in choosing between stand-alone or cage-plating. The authors observed better outcomes of stand-alone mostly in old adults than younger or middle age adults. Moreover, cage plating also help to reduce surgical duration, less intraoperative bleed and lower the rates of post-op dysphagia as well as adjacent segment degeneration. 37 Similarly, Tang et al (2023) also explained that the more the severity of myelopathy at pre-op, it may impact on the post op outcomes such as cervical lordosis and disc height that impact on long-term spinal stability and alignment. 38 Moreover, Lambrechts et al (2023) also found that anterior plating is more beneficial among more severe cases of myelopathy but the health-related quality of life may be somehow similar among adults. Stand-alone cages can do better to improve short-term dysphagia and adjacent segment disease, while cage plating increase structural support as well as alignment especially among severe myelopathy cases. 39 Therefore, it is essential to consider patient demographics, comorbidities and pre-operative severity of myelopathy may impact on the selection of technique of cages.
Fusion Rates and Stability
The overall fusion rate of 94% underscores the high success rate of anterior cervical corpectomy with expandable cages. However, the substantial heterogeneity in certain subgroups (I 2 = 91.81% in the stand-alone group) suggests that stand-alone cages may not consistently achieve the same level of fusion as cages with anterior plating (fusion rate of 0.94, I 2 = 57.36%). The lower fusion rate in the stand-alone group (0.89) highlights the potential limitations of using expandable cages without plating, especially in cases requiring greater biomechanical stability. The literature also reports similar findings, Cohn et al (2024) reported 92.1% fusion rates among patients treated with anterior plating with expandable cages as compared to 75.5% fusion rates in stand-alone. Moreover, the subsidence rate in expandable cages group is also lowered to 46% as compared to stand-alone cage 77.6%. 40 However, the fusion rates also depend upon the involvement of number of spinal segments in surgery. Abdul et al (2024) found that there is no significant difference between both techniques when there is single segment involvement. 41 Similar results were also reported by Elias et al, there is no significant difference of fusion rates among both techniques when there is one spinal segment involvement. 37 However, location of cage especially for stand-alone cage may also impact on the fusion rates eg, cranial placement of stand-alone cage showed better fusion rates as compared to caudal placement. Moreover, the use of expandable cages are reported with better outcomes when it is used with anterior plating, suggesting better clinical outcomes and lower subsidence rates because it improves C2-C7 cobb’s angle and Nurik’s score as compared to stand-alone cage and expandable cage without anterior plating. 24 So it appears that stand-alone cage could be used in single level corpectomy without significant pre operative instability or alignment problems but, this is questionable as it shows major drawbacks compared to expandable cage with anterior plating without evidence of major advantages. Therefore, there is need to consider all these discussed factors while choosing between expandable cages with anterior plating or stand-alone cages, to consider patients characteristics, needs and context of the surgery to optimize patients’ outcomes and reduce the complications.
Similarly, the overall stability rate was high (0.94), but the stand-alone cages showed a lower rate (0.83), reinforcing the clinical importance of anterior plating in enhancing both fusion and stability. The higher heterogeneity observed in the anterior plating group (I 2 = 64.67%) suggests that differences in plating techniques, cage designs, or patient factors may influence outcomes.
Complications: Dysphagia and Hardware-related Issues
The incidence of dysphagia was 0.16 overall, with considerable heterogeneity (I 2 = 89.4%). Stand-alone cages were associated with a significantly higher rate of dysphagia (0.34), compared to cages with anterior plating (0.08). The variability in dysphagia incidence could be due to the differences in cage design and surgical techniques. The higher incidence of dysphagia in the stand-alone cage group suggests that the lack of additional plating may increase mechanical stress on the oesophagus, leading to post-operative swallowing difficulties. The existing literature also reported varied results on demonstrating the association of dysphagia more in cases of stand-alone cases as compared to anterior plating with cages. However, Tang et al (2023) found that self-locking stand-alone cages incidence rate of dysphagia is lowered as compared to anterior plating cages. 38 On the other hand, Zavras et al (2022) also reported contrasted evidence as the authors reported a higher incidence of dysphagia among cages with anterior plating which showed inconsistency with the results of this study. 42 Moreover, Fayed et al (2021) also found no statistically significant difference of incidence of dysphagia due to cages with anterior plating and stand-alone cages. 43 Therefore, more comprehensive and detailed studies are needed to address this contrasting finding.
Hardware-related issues were present in 0.09 of cases, with substantial heterogeneity (I 2 = 65.31%). The group using expandable cages with anterior plating showed a lower incidence of hardware issues (0.07) compared to the group containing the stand-alone cages (0.15). While the heterogeneity in hardware-related issues may be influenced by differences in surgical technique or implant type, the overall lower rate in plated cages suggests that anterior plating contributes to greater implant stability and fewer complications. The similar incidence of hardware failure in expandable cages with anterior plating is also reported by Elias et al (2024). The authors demonstrated that the use of cage plating system in anterior corpectomy help to maintain disc height and cervical lordosis in better way as compared to stand-alone cages. It also explained the lower rates of subsidence and hardware failure issues. 37 Similarly, Tang et al (2023) while comparing both techniques demonstrated that expandable cage provide better height may less likely to cause any hardware failure in future due to its structural construct. 38 Therefore, it is well-document that the expandable cages with anterior plating is more favorable for better clinical outcomes through avoiding hardware failure.
Subsidence and Long-Term Outcomes
Subsidence was reported in 66 out of 454 patients, with a much higher incidence in the stand-alone cage group (13 patients) compared to the anterior plating group (2 patients). Subsidence can significantly impact long-term stability and spinal alignment, potentially leading to recurrence of symptoms or hardware failure. The increased subsidence in the stand-alone cage group highlights the clinical importance of anterior plating in preventing this complication.
Similarly, Jin et al (2021) also explained that there is more chances of symptoms recurrence and lower quality of life due to stand-alone cage subsidence in spinal fusion. It can result sinking into vertebral body that can result into segmental kyphosis, segmental issues and restenosis that results in increase pain and more neurological issues recurrence. 44 Noordhoek et al (2018) also estimated subsidence rates in their systematic review of 83% in stand-alone cage depending upon the surgery. 45 There are some factors which might also be consider to prevent subsidence. In another study, Ran et al (2024) found that there are also association between low bone mineral density, non-modular cylindrical cages, endplate removal after surgery and high subsidence rates as well as poor physical outcomes. 46 However, there are studies which indicate anterior plating with expandable cages not only reduced subsidence rates significantly but also enhanced clinical outcomes due to its stabilizing and supporting function in spinal construct 46 , 47 especially when there is multisegmented surgery. Therefore, these factors may help to comprehend and understand that subsidence can compromise surgical outcomes, particularly in multi-level procedures or patients with pre-existing instability, the use of anterior plating should be strongly considered to reduce the risk of long-term complications.
Visual Analogue Scale (VAS) and Outliers
VAS scores generally decreased across studies, reflecting pain relief after surgery. However, in Payer, 2006, VAS scores increased in both the traumatic fracture group and the chondrosarcoma group. This outlier highlights the potential for different clinical conditions to impact post-operative pain outcomes. The variability in VAS scores across studies underscores the need for careful patient selection and individualized surgical approaches, particularly in complex cases such as traumatic fractures or malignancies.
Hardware Failure Requiring Surgery
The overall incidence of hardware failure requiring surgery was 0.08, with higher rates in the stand-alone group (0.17) compared to the anterior plating group (0.05). This reinforces the importance of anterior plating in reducing the risk of hardware failure. The substantial heterogeneity observed in the hardware failure outcomes (I 2 = 60%) suggests that other factors, such as implant design, patient bone quality, or surgical technique, may influence the likelihood of requiring revision surgery.
Comparison to Other Surgical Techniques
Cervical corpectomy with expandable cages showed significant better clinical outcomes and quality of life reported in current literature. Prakash et al (2024) compared expandable with non-expandable cages and observed significant improvement in Nurick grade, pain among patients underwent surgery with expandable cages. 48 In another study, Yusupov et al (2021) used anchored expandable titanium cages which restored physiological sagittal cervical profile, enhanced sagittal alignment, height which remained stable for long duration of time. 31 While Das et al (2023) comparing directly to non-expandable cages, the authors found that the expandable cages showed more improvement in segmental angle and lower the incidence of subsidence while offering higher displacement and re-operation rates. 49 Therefore, clinical outcomes and quality of life significantly improve with anterior corpectomy surgery with expandable cages.
Our Study limitations is the heterogeneity between the studies in the term of, the reconstruction method used, the comparison to which each method compared and the limited number of the studies on each method particularly stand-alone cages which prevents further assessment and decreases the strength of the evidence on each method. Also the heterogeneity in the population characteristics including age, main complaint, specific diagnosis, indication of surgery, baseline neurological state, bone quality, surgical level, technical aspects as cage positioning and others make the evidence synthesis and interpretation very hard. The un availability of primary data regarding the patients’ specific factors or surgical techniques that may affect the outcomes like bone quality, surgical level and cage positioning for each cage type particularly, limits the evidence required to tailor the intervention for each patient. So future research should focus on larger randomized controlled trials to better understand the factors contributing to variability in outcomes, refine surgical techniques and reconstruction methods for optimal patient outcomes.
Conclusion
This meta-analysis provides a comprehensive overview of the clinical outcomes associated with anterior cervical corpectomy using expandable cages. While expandable cages offer significant advantages in terms of fusion, stability, and neurological recovery, the presence of substantial heterogeneity across studies suggests that patient-specific factors, cage design, and surgical technique all play a critical role in determining outcomes.
In particular, stand-alone expandable cages were associated with higher rates of complications, including dysphagia, subsidence, and hardware failure, compared to cages with anterior plating. These findings underscore the importance of considering anterior plating, particularly in cases requiring enhanced stability or where post-operative complications are a concern.
Future research should focus on larger randomized controlled trials to better understand the factors contributing to variability in outcomes and to refine surgical techniques for optimal patient outcomes. Moreover, attention should be given to long-term follow-up to capture late-onset complications such as subsidence and hardware-related issues.
Supplemental Material
Supplemental Material - Safety and Efficacy of Anterior Cervical Corpectomy and Reconstruction With Expandable Cages for Treatment of Cervical Myelopathy-Focusing on Stand-Alone Cages: A Systematic Review and Meta-Analysis
Supplemental Material for Safety and Efficacy of Anterior Cervical Corpectomy and Reconstruction With Expandable Cages for Treatment of Cervical Myelopathy-Focusing on Stand-Alone Cages: A Systematic Review and Meta-Analysis by Ahmed Mahmoud Abouelhamd, Mohamed Marey Hesn, Anas Elgenidy, Omar Alomari, Mohammed Al-mahdi Al-kurdi, Amer Helal, Ayman Abdelaziz Elgharori, Dina Hesham Khattab, Mohamed Gomaa Abdelrahim Farahat, Mahmoud Ragab Zaki Ali and Mohamed Hussein Hassan Tohamy in Global Spine Journal.
Author Contributions: Idea synthesis: MHHT, AA, AE, MMH. Database search: MMH. Screening, Data extraction: MMH, OA, MAMAK, DHK, AAE, MGAF, MRZA. Risk of bias assessment: OA, MAMAK, MMH. Data analysis: AE, MMH. Writing the original draft: AE, MMH, MHHT, AA, AH, OA, MAMAK, DHK, AAE, MGAF, MRZA. Reviewing, Editing and Supervision: MHHT, AA, AH, AE.
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Funding: The author(s) received no financial support for the research, authorship, and/or publication of this article.
Supplemental Material: Supplemental material for this article is available online.
Ethical Statements
Ethical Approval
Our study is a secondary study with the data used already published in previous studies, so we don’t need an ethical approval.
ORCID iDs
Ahmed Mahmoud Abouelhamd https://orcid.org/0000-0003-2702-4785
Mohamed Marey Hesn https://orcid.org/0000-0002-2444-5018
Mohamed Gomaa Farahat https://orcid.org/0009-0009-3282-8244
Mohamed Hussein Tohamy https://orcid.org/0000-0001-7577-4105
References
1. Hartmann S, Kavakebi P, Wipplinger C, et al. Retrospective analysis of cervical corpectomies: implant-related complications of one- and two-level corpectomies in 45 patients. Neurosurg Rev. 2018;41(1):285-290. doi: 10.1007/s10143-017-0854-8
2. Sastry RA, Yu J, Niu T, et al. Hardware failure and reoperation after hybrid anterior cervical corpectomy and discectomy for multilevel spondylotic disease: a retrospective single-institution cohort study. Interdiscip Neurosurg. 2021;25:101234. doi: 10.1016/j.inat.2021.101234
3. Gill M, Maheshwari V, Yadav AK, Gadhavi R. A clinicoradiological assessment following surgical intervention in patients of cervical spondylotic myelopathy: an institutional experience. Indian Journal of Neurosurgery. 2022;11(3):241-247. doi: 10.1055/s-0041-1726607
4. Woiciechowsky C. Distractable vertebral cages for reconstruction after cervical corpectomy. Spine. 2005;30(15):1736-1741. doi: 10.1097/01.brs.0000172158.31437.ce
5. Waschke A, Walter J, Duenisch P, Kalff R, Ewald C. Anterior cervical intercorporal fusion in patients with osteoporotic or tumorous fractures using a cement augmented cervical plate system first results of a prospective single-center study. J Spinal Disord Tech. 2013;26:E112-E117. doi: 10.1097/BSD.0b013e3182764b37
6. Cabraja M, Abbushi A, Kroppenstedt S, Woiciechowsky C. Cages with fixation wings versus cages plus plating for cervical reconstruction after corpectomy is there any difference? Cent Eur Neurosurg. 2010;71(2):59-63. doi: 10.1055/s-0029-1246135
7. Brenke C, Fischer S, Carolus A, Schmieder K, Ening G. Complications associated with cervical vertebral body replacement with expandable titanium cages. J Clin Neurosci. 2016;32:35-40. doi: 10.1016/j.jocn.2015.12.036
8. Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Syst Rev. 2021;10(1):89. doi: 10.1186/s13643-021-01626-4
9. Higgins JPT, Thomas J, Chandler J, et al. Cochrane Handbook for Systematic Reviews of Interventions. Wiley; 2019.
10. McGrath S, Zhao X, Steele R, Thombs BD, Benedetti A, Collaboration DepresSD (DEPRESSD) . Estimating the sample mean and standard deviation from commonly reported quantiles in meta-analysis. Stat Methods Med Res. 2020;29(9):2520-2537. doi: 10.1177/0962280219889080
11. Study quality assessment tools | NHLBI, NIH. Accessed May 1, 2024. https://www.nhlbi.nih.gov/health-topics/study-quality-assessment-tools
12. Lo CKL, Mertz D, Loeb M. Newcastle-Ottawa Scale: comparing reviewers’ to authors’ assessments. BMC Med Res Methodol. 2014;14:45. doi: 10.1186/1471-2288-14-45
13. Edoardo A, Zachary M. JBI Manual for Evidence Synthesis. In: Aromataris E, Munn Z, eds. Joanna Briggs Institute. 2024. doi: 10.46658/JBIMES-24-01
14. Balduzzi S, Rücker G, Schwarzer G. How to perform a meta-analysis with R: a practical tutorial. Evid Base Ment Health. 2019;22(4):153-160. doi: 10.1136/ebmental-2019-300117
15. Payer M. Implantation of a distractible titanium cage after cervical corpectomy: technical experience in 20 consecutive cases. Acta Neurochir. 2006;148(11):1173-1180. doi: 10.1007/s00701-006-0871-9
16. Deutscher Wirbelsäulenkongress Jahrestagung der Deutschen Wirbelsäulengesellschaft 8. – 10. Dezember 2011, Hamburg. Eur Spine J. 2011;20(11):2031,2053. doi: 10.1007/s00586-011-2033-x
17. Italian Spine Society National Congress SICV&GIS Naples . Italy may 11–13, 2017 ABSTRACTS. Eur Spine J. 2017;26(4):1328. doi: 10.1007/s00586-017-5051-5
18. Zaïri F, Aboukais R, Thines L, Allaoui M, Assaker R. Relevance of expandable titanium cage for the treatment of cervical spondylotic myelopathy. Eur Spine J. 2012;21(8):1545-1550. doi: 10.1007/s00586-012-2380-2
19. Perrini P, Gambacciani C, Martini C, Montemurro N, Lepori P. Anterior cervical corpectomy for cervical spondylotic myelopathy: reconstruction with expandable cylindrical cage versus iliac crest autograft. A retrospective study. Clin Neurol Neurosurg. 2015;139:258-263. doi: 10.1016/j.clineuro.2015.10.023
20. Tarantino R, Nigro L, Donnarumma P, Rullo M, Santoro A, Delfini R. Cervical reconstruction techniques. After adequate selection of the patient report of a series of 34 patients treated with winged expandable cages. Neurosurg Rev. 2017;40(2):281-286. doi: 10.1007/s10143-016-0770-3
21. Tohamy MH, Osterhoff G, Abdelgawaad AS, Ezzati A, Heyde CE. Anterior cervical corpectomy and fusion with stand-alone cages in patients with multilevel degenerative cervical spine disease is safe. BMC Muscoskelet Disord. 2022;23(1):20. doi: 10.1186/s12891-021-04883-5
22. Pojskic M, Saβ B, Nimsky C, Carl B. Application of an expandable cage for reconstruction of the cervical spine in a consecutive series of eighty-six patients. Medicina (Lithuania). 2020;56(12):1-15. doi: 10.3390/medicina56120642
23. König SA, Spetzger U. Distractable titanium cages versus PEEK cages versus iliac crest bone grafts for the replacement of cervical vertebrae. Minim Invasive Ther Allied Technol. 2014;23(2):102-105. doi: 10.3109/13645706.2013.854809
24. Seervi MK, Jain S, Purohit DK, Meena US. Evaluation of radiological and neurological outcomes after anterior cervical corpectomy with fusion using expandable cage alone and expandable cage with anterior cervical plating. Asian J Neurosurg. 2023;18(1):91-100. doi: 10.1055/s-0043-1761238
25. Cabraja M, Abbushi A, Koeppen D, Kroppenstedt S, Woiciechowsky C. Comparison between anterior and posterior decompression with instrumentation for cervical spondylotic myelopathy: sagittal alignment and clinical outcome. Neurosurg Focus. 2010;28(3):1-6. doi: 10.3171/2010.1.FOCUS09253
26. Zhang HY, Thongtrangan I, Le H, Park J, Kim DH. Expandable cage for cervical spine reconstruction. J Korean Neurosurg Soc. 2005;38(6):435-441. https://www.jkns.or.kr/journal/view.php?number=1993
27. Waschke A, Kaczor S, Walter J, Duenisch P, Kalff R, Ewald C. Expandable titanium cages for anterior column cervical reconstruction and their effect on sagittal profile: a review of 48 cases. Acta Neurochir. 2013;155(5):801-807. doi: 10.1007/s00701-013-1655-7
28. Burkett CJ, Baaj AA, Dakwar E, Uribe JS. Use of titanium expandable vertebral cages in cervical corpectomy. J Clin Neurosci. 2012;19(3):402-405. doi: 10.1016/j.jocn.2011.07.030
29. Pahwa N, Saha SK, Roy K, Pathak D, Bandyopadhyay S. Comparative study of expandable cage with integrated plate versus non expandable cage in cervical spine corpectomies. Asian J Med Sci. 2020;11(2):86-88. doi: 10.3126/ajms.v11i2.26515
30. Doria C, Mosele GR, Balsano M, Maestretti G, Caggiari G. Anterior decompression and plate fixation in treatment of cervical myelopathy: a multicentric retrospective review. Acta Orthop Traumatol Turcica. 2018;52(3):185-190. doi: 10.1016/j.aott.2017.12.003
31. Yusupov N, Siller S, Hofereiter J, et al. Vertebral body replacement with an anchored expandable titanium cage in the cervical spine: a clinical and radiological evaluation. Oper Neurosurg. 2020;20(1):109-118. doi: 10.1093/ons/opaa296
32. Alfieri A, Gazzeri R, Neroni M, Fiore C, Galarza M, Esposito S. Anterior expandable cylindrical cage reconstruction after cervical spinal metastasis resection. Clin Neurol Neurosurg. 2011;113(10):914-917. doi: 10.1016/j.clineuro.2011.02.023
33. Auguste KI, Chin C, Acosta FL, Ames CP. Expandable cylindrical cages in the cervical spine: a review of 22 cases. J Neurosurg Spine. 2006;4(4):285-291. doi: 10.3171/spi.2006.4.4.285
34. Omeis I, Bekelis K, Gregory A, et al. The use of expandable cages in patients undergoing multilevel corpectomies for metastatic tumors in the cervical spine. Orthopedics. 2010;33(2):87-92. doi: 10.3928/01477447-20100104-12
35. Chiriac A, Faiyad Z, Popescu C, Costachescu B, Poeata I. Our first experience with cervical expandable cage for vertebral body reconstruction. Romanian Neurosurgery. 2016;30(1):41-46. doi: 10.1097/BSD.0000000000000428
36. Weber MH, Fortin M, Shen J, et al. Graft subsidence and revision rates following anterior cervical corpectomy A clinical study comparing different interbody cages. 2016. https://www.clinicalspinesurgery.com/
37. Elias E, Daoud A, Smith J, Elias C, Nasser Z. Assessing surgical outcomes for cage plate system versus stand-alone C age in anterior cervical discectomy and fusion: a systematic review an d meta-analysis. World Neurosurg. 2024;185:150-164. doi: 10.1016/j.wneu.2024.02.079
38. Tang L, Liu X, Lu Y, Liu Y, Yu J, Zhao J. Clinical and imaging outcomes of self-locking stand-alone cages and anterior cage-with-plate in three-level anterior cervical discectomy and fusion: a retrospective comparative study. J Orthop Surg Res. 2023;18(1):276. doi: 10.1186/s13018-023-03726-4
39. Lambrechts MJ, Toci GR, Karamian BA, et al. Clinical improvements in myelopathy result in improved patient-reported outcomes following anterior cervical discectomy and fusion. Spine. 2023;48(5):321-329. doi: 10.1097/BRS.0000000000004518
40. Cohn P, Carbone J, Smith RA, et al. Radiographic fusion and subsidence rates for stand-alone cage versus anterior cage-plate construct in ACDF. Semin Spine Surg. 2024;36(3):101105.
41. Abdel HAWH, Khalil HI, Elsayed AM, Elmashad MG. A systematic review comparing fusion rates and cage subsidence in ACDF by cage alone vs cage and plate in multilevel cervical disc prolapse. QJM: Int J Med. 2024;117(Supplement_1):hcae070.359. doi: 10.1093/qjmed/hcae070.359
42. Zavras AG, Nolte MT, Sayari AJ, Singh K, Colman MW. Stand-alone cage versus anterior plating for 1-level and 2-level anterior cervical discectomy and fusion: a randomized controlled trial. Clin Spine Surg. 2022;35(4):155-165. doi: 10.1097/BSD.0000000000001332
43. Fayed I, Conte AG, Keating G, et al. Comparison of clinical and radiographic outcomes after standalone versus cage and plate constructs for anterior cervical discectomy and fusion. Internet J Spine Surg. 2021;15(3):403-412. doi: 10.14444/8060
44. Jin ZY, Teng Y, Wang HZ, Yang HL, Lu YJ, Gan MF. Comparative analysis of cage subsidence in anterior cervical decompression and fusion: zero profile anchored spacer (ROI-C) vs. Conventional cage and plate construct. Front Surg. 2021;8:736680. doi: 10.3389/fsurg.2021.736680
45. Noordhoek I, Koning MT, Jacobs WCH, Vleggeert-Lankamp CLA. Incidence and clinical relevance of cage subsidence in anterior cervical discectomy and fusion: a systematic review. Acta Neurochir. 2018;160(4):873-880. doi: 10.1007/s00701-018-3490-3
46. Ran L, Xie T, Zhao L, et al. MRI-based endplate bone quality score predicts cage subsidence following oblique lumbar interbody fusion. Spine J. 2024;24(10):1922-1928. doi: 10.1016/j.spinee.2024.05.002
47. Kim HC, Oh JK, Kim DS, et al. Comparison of the effectiveness and safety of bioactive glass ceramic to allograft bone for anterior cervical discectomy and fusion with anterior plate fixation. Neurosurg Rev. 2020;43(5):1423-1430. doi: 10.1007/s10143-019-01225-x
48. Prakash A, Bharti R, Chauhan G, Dutta G, Sahay CB. Outcome associated with use of winged expandable titanium cage following cervical corpectomy: an institutional experience. Egypt J Neurosurg. 2024;39(1):20. doi: 10.1186/s41984-024-00288-3
49. Das AK, Purohit DK, Gupta A, Kataria R. Comparison of radiological and clinical outcomes between expandable and non-expandable cages following cervical corpectomy: a systematic review and meta-analysis. Asian Spine J. 2023;17(3):567-581. doi: 10.31616/asj.2022.0179
Associated Data
Supplementary Materials
Supplemental Material - Safety and Efficacy of Anterior Cervical Corpectomy and Reconstruction With Expandable Cages for Treatment of Cervical Myelopathy-Focusing on Stand-Alone Cages: A Systematic Review and Meta-Analysis
Supplemental Material for Safety and Efficacy of Anterior Cervical Corpectomy and Reconstruction With Expandable Cages for Treatment of Cervical Myelopathy-Focusing on Stand-Alone Cages: A Systematic Review and Meta-Analysis by Ahmed Mahmoud Abouelhamd, Mohamed Marey Hesn, Anas Elgenidy, Omar Alomari, Mohammed Al-mahdi Al-kurdi, Amer Helal, Ayman Abdelaziz Elgharori, Dina Hesham Khattab, Mohamed Gomaa Abdelrahim Farahat, Mahmoud Ragab Zaki Ali and Mohamed Hussein Hassan Tohamy in Global Spine Journal.