MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.semarthrit.2020.11.011

Медицинская библиотека · Seminars in arthritis and rheumatism · 2021

Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise.

Christiansen Sara Nysom, Filippou Georgios, Scirè Carlo Alberto, Balint Peter V, Bruyn George Aw, Dalbeth Nicola, Dejaco Christian, Sedie Andrea Delle, Filippucci Emilio, Hammer Hilde B, Iagnocco Annamaria, Keen Helen I, Kissin Eugene Y, Koski Juhani, Mandl Peter, Martin Julia, Miguel Eugenio De, Möller Ingrid, Naredo Esperanza, Pineda Carlos, Schmidt Wolfgang A, Stewart Sarah, Antonietta D'Agostino Maria, Terslev Lene, on the behalf of the OMERACT Ultrasound working group

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises.

METHODS

Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system.

RESULTS

Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67).

CONCLUSION

A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.

Для цитирования: Christiansen Sara Nysom, Filippou Georgios, Scirè Carlo Alberto, Balint Peter V, Bruyn George Aw, Dalbeth Nicola, Dejaco Christian, Sedie Andrea Delle, Filippucci Emilio, Hammer Hilde B, Iagnocco Annamaria, Keen Helen I, Kissin Eugene Y, Koski Juhani, Mandl Peter, Martin Julia, Miguel Eugenio De, Möller Ingrid, Naredo Esperanza, Pineda Carlos, Schmidt Wolfgang A, Stewart Sarah, Antonietta D'Agostino Maria, Terslev Lene, on the behalf of the OMERACT Ultrasound working group. Consensus-based semi-quantitative ultrasound scoring system for gout lesions: Results of an OMERACT Delphi process and web-reliability exercise.. Seminars in arthritis and rheumatism. 2021. DOI: 10.1016/j.semarthrit.2020.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.