DOI 10.1016/j.spinee.2010.06.008
Salvage percutaneous vertebral augmentation in failed spinal interbody fusions associated with multiple myeloma.
Аннотация
BACKGROUND CONTEXT: Failed posterior spinal interbody fusion is a known phenomenon with clinical consequences.
PURPOSE: This technical note of percutaneous vertebral augmentation in patients with failed posterior interbody construct can be used in patients at high risk for repeat surgery, like patients with multiple myeloma.
STUDY DESIGN/
SETTING
Retrospective analysis of the two procedures was done. Clinical and radiologic follow-up was available for 1.5 years at the time of manuscript preparation.
PATIENT SAMPLE: Both patients were referred to us after undergoing posterior spinal interbody fusion from outside institutions with persistent pain. The patients had a pain level requiring opioid analgesics and changes in the activities of daily living. The patients had active multiple myeloma at the time of the surgical intervention and vertebral augmentation procedure.
OUTCOME MEASURES: Visual analog scales were used to gauge the pain relief after the procedure and during further follow-ups. In addition, radiologic follow-up was obtained by means of computed tomography and magnetic resonance imaging scans.
METHODS
Vertebral augmentation procedures in both patients were done under intravenous conscious sedation with the patient prone. High-quality biplane fluoroscopy was used for the procedure. No immediate- or long-term complications were noted.
RESULTS
Both patients had an appreciable relief from pain immediately after the procedure and on follow-up. Follow-up radiologic imaging revealed consistent cement distribution around the construct, no further collapse of the vertebra, with no new lucency surrounding the construct.
CONCLUSIONS
This modified technique of vertebral augmentation can be helpful in management of cases with clinical or radiologic evidence of failed posterior spinal interbody fusion. The cage construct can be stabilized with the injection of cement. The cement surrounding the construct provides strength to the axis and prevents further loosening.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.