BACKGROUND

The objective of this study was to examine the impact of varying taper dimensions and different forms of bioceramic sealers on the fracture resistance of mandibular premolar teeth prepared using single-file Ni-Ti instrumentation systems in vitro.

METHODS

Forty single-rooted mandibular premolars were randomly allocated into four groups (n = 10) according to the taper value and type of sealer used: Group T4-AHBC - 25/0.04 taper with AH Plus BCS (premixed syringe form), Group T6-AHBC - 25/0.06 taper with AH Plus BCS, Group T4-BRCS - 25/0.04 taper with BioRoot RCS (powder-liquid form), and Group T6-BRCS - 25/0.06 taper with BioRoot RCS. Root canals were prepared and then obturated with the designated sealers. Using a universal testing machine at a crosshead speed of 1 mm/min, fracture resistance was measured, and the resulting data were analyzed statistically.

RESULTS

Statistical analysis revealed that there were no significant differences in fracture resistance between the groups (p = 0.188). Neither the taper value nor the bioceramic sealer form had a significant effect on fracture resistance.

CONCLUSIONS

Within the limitations of this in vitro study, variation in taper values and sealer forms did not affect fracture resistance. Both powder-liquid and premixed syringe forms demonstrated similar performance, suggesting that clinicians may choose between them based on handling preference and clinical practicality.

Для цитирования: Şirinoğlu Ebru, Kaşıkçı Sena. Effect of different taper values and bioceramic sealer forms on fracture resistance of mandibular premolars prepared with single-file Ni-Ti systems: an in vitro study.. BMC oral health. 2025. DOI: 10.1186/s12903-025-06670-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.