Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?

Jungwirth-Weinberger Anna, Hanreich Carola, Kasparek Maximilian F, Renner Lisa, Waldstein Wenzel, Boettner Friedrich

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Increased cobalt (Co) and chromium (Cr) serum levels are one reason for revision surgery in metal on metal (MoM) total hip arthroplasty (THA) patients. Dual mobility liners are a simple revision option; however, they preserve the metal shell and stem and it is therefore not clear if metal ion levels will fully normalize after revision surgery.

MATERIAL AND

METHODS

Between April 2013 and December 2017 25 hips (24 patients) underwent revision from a MoM THA to an off-label dual mobility liner. Five patients were lost to follow-up and one patient refused leaving 18 patients (11 men, 7 female, average age 63.9 years) for pre- and postoperative metal ion level blood tests at a minimum follow-up of 2 years.

RESULTS

Fourteen patients were revised for osteolysis, two for elevated metal ion levels and two for fluid or cysts around the femoral or acetabular component. The average preoperative Co and Cr levels were 8.3 µg/l and 5.0 µg/l, respectively. At a minimum follow-up of 2 years (30-95 months), metal ions dropped to 0.8 µg/l. Harris Hip Score (HHS), Hip Osteoarthritis Outcome Score (HOOS), Visual Analog Scale (VAS) and the UCLA activity score improved non-significantly from pre- to postoperative. There was one postoperative complication in the study cohort. One patient with persisting pain required revision surgery to a standard acetabular component during the follow-up period.

CONCLUSION

The off-label use of a dual-mobility liner in the current study resulted in normalization of the metal ion levels suggesting that preserving the cobalt-chromium acetabular component has little impact on ion levels. In addition, dual mobility liners have a low complication and revision rate.

Для цитирования: Jungwirth-Weinberger Anna, Hanreich Carola, Kasparek Maximilian F, Renner Lisa, Waldstein Wenzel, Boettner Friedrich. Do cobalt and chromium blood metal ion levels normalize after revision of failed metal-on-metal total hip replacements?. Archives of orthopaedic and trauma surgery. 2021. DOI: 10.1007/s00402-021-04206-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.