DOI 10.1186/s12938-024-01262-8
Plate fixation of inferior ramus in pubis-ischium ramus improves mechanical stability in Tile B pelvic injures: a cadaveric biomechanical analysis and early clinical experience.
Аннотация
BACKGROUND
Management of inferior ramus of the pubis-ischium ramus remains controversial, and related research is sparse. The main intention of this study is to describe the biomechanical and clinical outcomes of pubis-ischium ramus fractures in Tile B pelvic injuries and to identify the feasibility and necessity of fixation of the inferior ramus of the pubis-ischium ramus.
METHODS
This study comprised two parts: a biomechanical test and a retrospective clinical study. For the biomechanical tests, Tile B-type pelvic injuries were modeled in six cadaver specimens by performing pubis-ischium osteotomies and disruption of the anterior and interosseous sacroiliac ligaments. The superior and/or inferior rami of the pubis-ischium ramus were repaired with reconstruction plates and separated into three groups (A, B, and C). Specimens were placed in the standing position and were loaded axially with two-leg support for three cycles at 500 N. The displacements of sacroiliac joints at osteotomy were measured with Vernier calipers and compared using statistical software. To investigate the clinical outcomes of this technique, 26 patients were retrospectively analyzed and divided into a superior ramus fixation group (Group D) and a combined superior and inferior ramus of the pubis-ischium ramus fixation group (Group E). The main outcome measures were time of operation, blood loss, postoperative radiographic reduction grading, and functional outcomes.
RESULTS
In the vertical loading test, Group E showed better pelvic ring stability than Group D (P < 0.05). However, the shift of the sacroiliac joints was almost identical among the three groups. In our clinical case series, all fractures in Group E achieved bony union. Group E demonstrated earlier weight-bearing functional exercise (2.54 ± 1.45 vs 4.77 ± 2.09; P = 0.004), earlier bony union (13.23 ± 2.89 vs 16.55 ± 3.11; P = 0.013), and better functional outcomes (89.77 ± 7.27 vs 82.38 ± 8.81; P = 0.028) than Group D. The incidence of sexual dysfunction was significantly lower in Group E than that in Group D (2/13 vs 7/13; P = 0.039). Bone nonunion occurred in two patients in Group D, and two patients in Group E had heterotopic ossification. None of the patients exhibited wound complications, infections, implant failures, or bone-implant interface failures.
CONCLUSIONS
Fixation of the inferior ramus of a pubis-ischium ramus fracture based on conventional fixation of the anterior pelvic ring is mechanically superior in cadaveric Tile B pelvic injury and shows rapid recovery, good functional outcomes, and low incidence of complications.