Sirotti Silvia, Terslev Lene, Filippucci Emilio, Iagnocco Annamaria, Moller Ingrid, Naredo Esperanza, Vreju Florentin A, Adinolfi Antonella, Becce Fabio, Hammer Hilde Berner, Cazenave Tomas, Cipolletta Edoardo, Christiansen Sara Nysom, Delle Sedie Andrea, Diaz Mario, Figus Fabiana, Mandl Peter, MacCarter Daryl, Mortada Mohamed A, Mouterde Gael, Porta Francesco, Reginato Anthony M, Schmidt Wolfgang A, Serban Teodora, Wakefield Richard J, Zufferey Pascal, Sarzi-Puttini Piercarlo, Zanetti Anna, Damiani Arianna, Pineda Carlos, Keen Helen I, D'Agostino Maria Antonietta, Filippou Georgios, OMERACT Ultrasound working group-CPPD subgroup
Аннотация
METHODS: In this study the novel scoring system for CPPD was developed through a stepwise process, following an established OMERACT ultrasound methodology. Following a previous systematic review to gather available evidence on existing scoring systems for CPPD, the novel scoring system was developed through a Delphi survey based on the expert opinion of the members of the OMERACT Ultrasound working group-CPPD subgroup. The reliability of the scoring system was then tested on a web-based and patient-based exercise. Intra-reader and inter-reader reliability of the new scoring system was assessed using weighted Light's κ coefficients.
FINDINGS: The four-grade semiquantitative scoring system consisted of: grade 0 (no findings consistent with CPPD), grade 1 (≤3 single spots or 1 small deposit), grade 2 (>3 single spots or >1 small deposit or ≥1 larger deposit occupying ≤50% of the structure under examination in the reference image-ie, the scanning view with the highest grade of depositions), and grade 3 (deposits that occupy more than 50% of the structure under examination in the reference image). The score should be applied to the knee (menisci and hyaline cartilage) and the triangular fibrocartilage complex of the wrist. The intra-reader and inter-reader reliabilities on static images were almost perfect (κ 0·90 [95% CI 0·79-1·00] and κ 0·84 [0·79-0·88]), and on the eight patients recruited (four [50%] female and four [50%] male) were substantial (κ 0·72 [95% CI 0·47 to 0·96] and 0·66 [0·61 to 0·71]).
INTERPRETATION: This OMERACT ultrasound scoring system for CPPD was reliable on both static images and patients. The scoring system might be a valuable tool for ensuring valid and comparable results in clinical trials and could help monitor the extent of crystal deposition in patients with CPPD in clinical practice.
FUNDING: The Italian Ministry of Health - Ricerca Corrente.