DOI 10.1016/s0278-2391(96)90483-8
Stability of maxilla downgrafting after rigid or wire fixation.
Аннотация
PURPOSE: This article compares the long-term outcomes of rigid internal fixation with wire fixation.
PATIENTS AND
METHODS
In this retrospective study, nine cases of vertical midface augmentation in which rigid fixation was used were compared with 11 cases with wire fixation. One surgeon completed all cases for the rigid fixation group, and another surgeon completed the cases in the wire fixation group.
RESULTS
Follow-up was 16 +/- 11 months for the rigid fixation group and 20 +/- 12 months for the wire fixation group. Inferior movement at the anterior portion of the maxilla was 7.0 +/- 2.9 mm with rigid fixation and 4.5 +/- 3.6 mm with wire fixation (P < .05). Postsurgical superior movement (relapse) was 0.4 +/- 0.4 mm with rigid fixation and 2.4 +/- 2.4 mm with wire fixation (P < .01). Inferior movement at the posterior maxilla was 3.1 +/- 0.2 mm with rigid fixation and 2.8 +/- 2.3 mm with wire fixation. Postsurgical superior movement (relapse) was 0.8 +/- 0.4 mm with rigid fixation and 0.5 +/- 2.3 mm with wire fixation, which was not significantly different.
CONCLUSION
This comparison showed downgrafting of the maxilla using autogenous bone harvested from the iliac crest and rigid internal fixation to be a predictable and stable procedure.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.