m+Medelevator.RU
← Поиск публикаций
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021

Polyethylene liner cementation into a well-fixed metal acetabular shell for the management of periacetabular osteolysis: a systematic review.

Систематический обзорСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Malahias Michael-Alexander, Ma Qian-Li, Jang Seong J, Loucas Marios, Gu Alex, Gkiatas Ioannis, Sedran Jean-Claude, Nikolaou Vasileios S, Sculco Peter K

Аннотация

PURPOSE: Although various papers have reported on the clinical performance of cup retention with cementation of a new liner and bone grafting in the management of well-fixed cups with polyethylene wear and periacetabular osteolysis after total hip arthroplasty (THA), no systematic review of this topic has been published to date.

METHODS: Medline, EMBASE and Cochrane Library were searched for articles published from January 1999 to January 2019 using "osteolysis" AND "well-fixed", "osteolysis" AND "retro-acetabular", "bone graft" AND ("retention" OR "retained" OR "stable") AND "cup", and "cemented liner" AND "well-fixed".

RESULTS: Nine articles were selected for review (186 cases, 76.1 months mean follow-up). The overall revision rate was 11.3% (21 hips) most commonly due to aseptic loosening (9/186 hips), dislocation (8/186 hips), and liner wear progression (2/186 cases). The reported square size of osteolytic lesions ranged from a mean of 465.84 mm2 to a max of 4,770 mm2. Almost all reported lesions treated with bone grafts resolved or did not progress 97% (72/74). All studies indicated improved pain and functional scores at follow-up.

CONCLUSION: Cementation of a new liner with periacetabular bone grafting provides an alternative option to isolated liner exchange and cup revision for the management of periacetabular osteolysis in well-fixed cups with a disrupted locking mechanism or unavailable exchange liner. Further higher quality studies are required in order to examine if the use of highly cross-linked polyethylene, highly porous-coated cups, hydroxyapatite-coated cups, and small-diameter cups influence the clinical outcome of liner cementation in well-fixed cups with periacetabular osteolysis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты