MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bmjopen-2020-048444

Медицинская библиотека · BMJ open · 2021

Construct validity of a clinically correlated knee osteoarthritis ultrasonographic scale: a cross-sectional observational study.

Mortada Mohamed, Dawa Ghada A, Amer Youmna A

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To assess the validity of a novel ultrasonographic scale for knee osteoarthritis (KOA) and its relation with the degree of pain and clinical features.

DESIGN

A cross-sectional observational study including 245 patients with knee pain who fulfilled the American College of Rheumatology criteria for KOA. All patients were subjected to clinical assessment Western Ontario and McMaster Universities Index of Osteoarthritis (WOMAC) scale, global visual analogue scale (VAS) and functional assessment through the use of Health Assessment Questionnaire-II (HAQ-II). Ultrasonographic assessment was conducted following ZAGAZIG scale comprising five domains: one for degenerative features (one-third of total score) and the other four for inflammatory features (two-thirds of score).

RESULTS

There were positive correlations between ZAGAZIG score and all WOMAC subscales (pain, stiffness and function) (r=0.71, p=0.00; r=0.62, p=0.00; r=0.70, p=0.00, respectively).Moreover, there was a strong positive correlation between ZAGAZIG scale and both VAS and HAQ-II (r=0.82, p=0.00 and r=0.67, p=0.00). At cut-off point of >5, total US score distinguishes between patients with KOA with no or mild pain and those with moderate pain (87.2 sensitivity and 87.2 specificity). At cut-off point of 7, total score of ZAGAZIG scale distinguishes between patients with KOA with moderate pain and those with severe pain (94.5 sensitivity and 42.5 specificity).

CONCLUSION

ZAGAZIG scale constitutes a validated tool for KOA assessment. ZAGAZIG scale correlated with WOMAC subscales (pain, stiffness and function), VAS and HAQ.

Для цитирования: Mortada Mohamed, Dawa Ghada A, Amer Youmna A. Construct validity of a clinically correlated knee osteoarthritis ultrasonographic scale: a cross-sectional observational study.. BMJ open. 2021. DOI: 10.1136/bmjopen-2020-048444.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.