OBJECTIVES
The purpose of this study was to compare two different designs of three-dimensional osteosynthesis plates for their suitability in the treatment of mandibular angle fractures in terms of sufficient fracture healing and concomitant complications.
MATERIALS AND
METHODS
Retrospectively a total of 54 patients with 56 mandibular angle fractures were evaluated. Two different types of three-dimensional plates from the Medartis Trilock system were analyzed: (A) Square design plate (☐-plate) with a thickness of 1.0 mm, and (B) triangular-shaped 3D-plate (△-plate) with a thickness of 1.3 mm. Patient demographics, fracture mechanism and intraoperative details were recorded during an average follow-up period of 1 year.
RESULTS
The utilization of △-plates was observed to entail a considerably lengthier surgical time in contrast to ☐-plate systems (P = 0.037). The application of △-plate showed a tendency of higher incidence of major complications than ☐-plate (P = 0.06), as evidenced by the occurrence of non-union in 2 out of 22 cases, resulting in higher surgical revision rate for △-plate (P = 0.027).
CONCLUSION
Sufficient treatment of mandibular angle fractures is feasible by using 1.0 mm thick, square shaped three-dimensional plate systems. The use of thicker three-dimensional osteosynthesis plates seems to significantly increase the operating time and complication rates, whereby the geometry of the plate seems to have an influence.
CLINICAL RELEVANCE: The plate design could have an impact on treatment outcomes of mandibular angle fractures.
TRIAL REGISTRATION NUMBER: Not applicable.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.