MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1051/sicotj/2021045

Медицинская библиотека · SICOT-J · 2021

Femoral head penetration in Vitamin-E polyethylene liner versus conventional liners in total hip arthroplasty: systematic review and meta-analysis of randomised control trials.

Elbardesy Hany, Yadav Himanshu, Rabea Mohamed, Guerin Shane, Harty James

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Debate encompasses the use of Vitamin E Polyethylene or conventional Polyethylene liner in primary hip arthroplasty. Does the Inclusion of Vitamin E in PE give adequate protection from oxidation and maintains lower rates of wear?

PATIENTS AND

METHODS

We performed this study following the Preferred Reporting Items for Systematic Reviews and Meta-analyses Statement (PRISMA) and the Cochrane Handbook for systematic reviews and meta-analysis. Studies were included from any region, written in any language. We had only the randomised control trials comparing the femoral head penetration between Vitamin-E diffused highly cross-linked polyethylene (VEPE) liner and conventional liners in primary total hip arthroplasty.

RESULTS

We included 10 studies in this meta-analysis. We conducted them using Review Manager V.5.0. We computed the risk ratio to measure the treatment effect, considering the heterogeneity. We used Random-effect models. VEPE had insignificant marginal advantages for FHP within three months post-operative. Additionally, VEPE showed significantly less FHP after two and five years. After one year, it showed significantly less FHP with the VEPE group versus the UHMWPE cohort and a non-significant difference between the VEPE and XLPE group.

CONCLUSIONS

In terms of FHP, this metanalysis shows less FHP for the VEPE than conventional PE. A longer follow-up period is required to evaluate whether the oxidation protection gained by Vitamin E results in lower wear rates, less osteolysis, and aseptic loosening compared to the conventional PE in the long term.

Для цитирования: Elbardesy Hany, Yadav Himanshu, Rabea Mohamed, Guerin Shane, Harty James. Femoral head penetration in Vitamin-E polyethylene liner versus conventional liners in total hip arthroplasty: systematic review and meta-analysis of randomised control trials.. SICOT-J. 2021. DOI: 10.1051/sicotj/2021045.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.