MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00590-023-03540-y

Медицинская библиотека · European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023

Metal-on-metal metaphyseal and ceramic-on-ceramic femoral neck arthroplasty: the impact on clinical results, oxidative stress and concentration of metal ions in serum and blood.

Stołtny Tomasz, Dobrakowski Michał, Augustyn Aleksander, Kasperczyk Sławomir, Rokicka Dominika, Skowroński Rafał, Strojek Krzysztof, Koczy Bogdan

СтатьяПеревод в очереди

Аннотация

PURPOSE: Growing number of hip arthroplasty in Poland performed with the use of metaphyseal stems results from the decreasing age of patients qualified for procedures and is consistent with the corresponding trends in European countries. To this day, a significant population functions after undergoing hip replacement using metal-on-metal implant. This study was aimed at the assessment of the variability of the oxidative system, as well as the concentrations of chromium and cobalt ions in serum and blood and their potential impact on postoperative clinical status.

MATERIAL AND

METHODS

The analysis included 58 men. The first group-operated using J&J DePuy ASR metal-on-metal implant with metaphyseal stem ProximaTm. Second group-operated using K-Implant SPIRON® femoral neck prosthesis in full ceramic articulation. Selected parameters of oxidative stress and the antioxidant system as well as the concentration of metal ions in blood were determined twice. Each patient underwent two clinical evaluations using acclaimed physical examination scale systems.

RESULTS

In the first group, significantly higher concentrations of Cr (p = 0.028) and Co (p = 0.002) were demonstrated compared to the group of femoral neck arthroplasty. The mean concentrations of Cr and Co, 10.45 and 9.26 μg/l, respectively, were higher in patients operated bilaterally. In the ASR group, greater pain intensity in the operated hip and higher indicators of oxidative stress were found.

CONCLUSIONS

Metal-on-metal articulation of the hip significantly increases the concentration of Cr and Co in blood, induces oxidative stress and modifies function of the antioxidant system and generates greater pain in the operated hip.

Для цитирования: Stołtny Tomasz, Dobrakowski Michał, Augustyn Aleksander, Kasperczyk Sławomir, Rokicka Dominika, Skowroński Rafał, Strojek Krzysztof, Koczy Bogdan. Metal-on-metal metaphyseal and ceramic-on-ceramic femoral neck arthroplasty: the impact on clinical results, oxidative stress and concentration of metal ions in serum and blood.. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2023. DOI: 10.1007/s00590-023-03540-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.