m+Medelevator.RU
← Поиск публикаций
The British journal of ophthalmology · 2021

Management of limbal stem cell deficiency by amnion-assisted conjunctival epithelial redirection using vacuum-dried amniotic membrane and fibrin glue.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dua Harminder Singh, Ting Darren Shu Jeng, AlSaadi Ahmed, Said Dalia G

Аннотация

PURPOSE: To study the outcome of a modified amnion-assisted conjunctival epithelial redirection (ACER) technique using vacuum-dried amnion (Omnigen) and fibrin glue for managing total limbal stem cell deficiency (LSCD).

METHOD: A retrospective, interventional case series of all patients with total LSCD who underwent limbal stem cell transplant (LSCT) using the modified ACER procedure between 2016 and 2019. The outcome was defined as: (1) success: complete corneal re-epithelialisation without conjunctivalisation; (2) partial success: sub-total corneal re-epithelialisation with partial non-progressive conjunctivalisation sparing the visual axis and (3) failure: conjunctivalisation affecting the visual axis.

RESULTS: Ten patients (six men), with a mean age of 46.2±18.4 years, were included. The mean follow-up was 23.0±13.9 months. Causes of LSCD were chemical eye injury (30%), congenital aniridia-related keratopathy (30%), ocular surface malignancy (20%), Steven-Johnson syndrome (10%) and contact lens overuse (10%). 50% were bilateral. The time from diagnosis to ACER (for acquired causes) was 45.6±44.4 months. 80% of patients achieved a complete/partial success following ACER and 20% of patients required repeat LSCT. Auto-LSCT was associated with a significantly higher chance of success than allo-LSCT (p=0.048). The mean best-corrected-visual-acuity (logMAR) improved significantly from 1.76±0.64 preoperatively to 0.94±0.94 at final follow-up (p=0.009). Omnigen was available off-the-shelf stored at room temperature and its transparency enabled visualisation of the healing epithelium beneath.

CONCLUSION: LSCT using the modified ACER serves as an effective ocular surface reconstruction technique in managing total LSCD and improving vision. Vacuum-dried amnion provides advantages of easy handling, transparency and storage at room temperature.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты