Journal of neural engineering · 2025

Towards a closed loop retinal prosthesis: measuring electrically evoked retinal responses using large electrodes.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Spencer Martin J, Hosie Suzanne, Tong Wei, Shivdasani Mohit N, Garrett David J, De León Sorel E, Brunton Emma K, Kameneva Tatiana, Grayden David B, Fallon James B, Ibbotson Michael R, Burkitt Anthony N, Meffin Hamish

Аннотация

Objective.Sensory prostheses use arrays of electrodes to stimulate neural tissue and restore a sense of vision or hearing. At perceptible levels of stimulation, the current from each electrode spreads and causes overlapping regions of neural activation. This lack of specificity results in perceptual deficits. Methods to overcome this reduced specificity, such as a closed loop stimulation approach require measurement of the neural response to stimulation. This investigation tests the possibility of using the large stimulating electrodes such as those required by some subretinal or suprachoroidal retinal implants to measure the neural response to stimulation, an approach similar to Evoked Compound Action Potentials measurements used in cochlear implants.Approach. Ex vivotissue samples from Long Evans rats with healthy retinas and Royal College of Surgeon rats with retinal degeneration were used to investigate both stimulating and recording from electrodes of the same array. A hexagonal array was used with 20 platinum electrodes with 500μm diameter and 700μm pitch. Post-stimulus voltage decay was reduced with appropriate tuning of a triphasic stimulation pulse and in post-analysis with a high-pass filter. A method using alternating polarities of biphasic pulses was also trialed. A cocktail of synaptic and ion channel blockers was used to block all neural response including action potentials and thus confirm the biological origin of the signal.Main Results.It was found that a neural signal was observable on electrode that were sufficiently distant from the stimulating electrodes. The signal appeared to be due to direct activation of ganglion cells or possibly mediated via inner retinal neurons.Significance.This result confirms that recording usable neural signals from large electrodes is possible, which is an essential step in implementing a closed loop stimulation strategy for a subretinal or suprachoroidal retinal prosthesis.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты