Low reoperation rate after fixation of displaced femoral neck fractures with the femoral neck system (FNS).

Obey Mitchel R, Falgons Christian G, Eastman Jonathan G, Choo Andrew M, Achor Timothy S, Munz John W, Warner Stephen J

СтатьяПеревод в очереди

Аннотация

PURPOSE: Operative fixation of femoral neck fractures (FNFs) remains challenging. Complications are not infrequent, especially in displaced patterns. Numerous fixation techniques have been previously described in the literature; however, there remains a paucity of data regarding outcomes of these injuries treated with the femoral neck system (FNS).

METHODS

Patients with a displaced FNF (OTA/AO 31B) treated with the FNS at a single level 1 academic trauma center between 1/1/2019 and 1/1/2023 were identified. Radiographs were reviewed to assess fracture displacement, location, and characteristics. Patient records were further reviewed to assess for complications, reoperations, and osseous union.

RESULTS

Forty-three patients (65% male) with 44 FNFs were identified with a mean age of 35.0 years (range, 13-61 years). Two patients developed a deep infection requiring surgical debridement, four patients underwent a total hip arthroplasty, and one patient underwent a valgus intertrochanteric osteotomy for nonunion. There were three cases of femoral head AVN. Mean follow-up was 482.5 days among all patients, and 36 fractures had at least 6 months of follow-up or reached bony union.

CONCLUSIONS

Here, we present a series of patients treated with the FNS for internal fixation and report a 18% reoperation rate. This is lower than the average rate that has been previously reported in similar patient populations in the literature treated with alternative methods of internal fixation. Thus, the FNS appears to be a safe and effective option for treatment of these injuries.

Для цитирования: Obey Mitchel R, Falgons Christian G, Eastman Jonathan G, Choo Andrew M, Achor Timothy S, Munz John W, Warner Stephen J. Low reoperation rate after fixation of displaced femoral neck fractures with the femoral neck system (FNS).. European journal of orthopaedic surgery & traumatology : orthopedie traumatologie. 2024. DOI: 10.1007/s00590-024-03962-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.