International orthopaedics · 2011
Contemporary femoral designs in total knee arthroplasty: effects on the patello-femoral congruence.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Indelli Pier Francesco, Marcucci Massimiliano, Cariello Donatella, Poli Paolo, Innocenti Massimo
Аннотация
PURPOSE: The objective of this study was to evaluate the radiological and clinical correlations between implant design and patellar positioning in patients who underwent TKA utilizing femoral implants with modern designs.
METHODS: Thirty consecutive PFC PS Sigma TKAs, characterized by a new prolonged anterior flange and a "smoother" trochlea, were prospectively reviewed. All patellae were replaced. All patients were evaluated pre-operatively and prospectively at two years follow-up both clinically according to the Knee Society score as well as radiographically. This included computed tomography (CT); patellar tilt, patellar conformity angle, patellar lateralization, and femoral component external-rotation in relation to the clinical trans-epicondylar axis.
RESULTS: Average patellar tilt at follow-up was 3° (±7.5°) with respect to a pre-operative 18.5° (±8.5°). Average patellar congruence angle at follow-up was -3° (range, -11° to +9°) with respect to a pre-operative 10.3° (range, + 1.5° to 25.5°). Average lateralization index at follow-up was 2.7 mm (range, -3.4 mm to +7.1 mm) with respect to a pre-operative 12.2 mm (± 4.8 mm). Femoral component positioning related to the trans-epicondylar axis showed an external rotation of 2.80° (± 2.10°) at follow-up with respect to 5.7° (± 1.80°). Clinically, two (6.6%) patients reported patello-femoral complications related to imperfections in the surgical technique more than the implant's design.
CONCLUSIONS: This study highlighted that modern femoral designs in TKA allow for a correct reproducibility of a normal patello-femoral conformity. Strict surgical principles are paramount to avoid patello-femoral complications even when modern implants are used.
METHODS: Thirty consecutive PFC PS Sigma TKAs, characterized by a new prolonged anterior flange and a "smoother" trochlea, were prospectively reviewed. All patellae were replaced. All patients were evaluated pre-operatively and prospectively at two years follow-up both clinically according to the Knee Society score as well as radiographically. This included computed tomography (CT); patellar tilt, patellar conformity angle, patellar lateralization, and femoral component external-rotation in relation to the clinical trans-epicondylar axis.
RESULTS: Average patellar tilt at follow-up was 3° (±7.5°) with respect to a pre-operative 18.5° (±8.5°). Average patellar congruence angle at follow-up was -3° (range, -11° to +9°) with respect to a pre-operative 10.3° (range, + 1.5° to 25.5°). Average lateralization index at follow-up was 2.7 mm (range, -3.4 mm to +7.1 mm) with respect to a pre-operative 12.2 mm (± 4.8 mm). Femoral component positioning related to the trans-epicondylar axis showed an external rotation of 2.80° (± 2.10°) at follow-up with respect to 5.7° (± 1.80°). Clinically, two (6.6%) patients reported patello-femoral complications related to imperfections in the surgical technique more than the implant's design.
CONCLUSIONS: This study highlighted that modern femoral designs in TKA allow for a correct reproducibility of a normal patello-femoral conformity. Strict surgical principles are paramount to avoid patello-femoral complications even when modern implants are used.