MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2011.10.016

Медицинская библиотека · Journal of shoulder and elbow surgery · 2011

Comparisons of glenoid bony defects between normal cadaveric specimens and patients with recurrent shoulder dislocation: an anatomic study.

Ji Jong-Hun, Kwak Dai-Soon, Yang Po-Song, Kwon Min Jeong, Han Seung-Ho, Jeong Jae-Jung

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The location and degree of bony defects that can affect clinical outcomes remains controversial in recurrent shoulder dislocation. The purpose of this study was to define the most common location of glenoid bony defects in patients with recurrent shoulder dislocation.

MATERIALS AND

METHODS

We analyzed the shape and aspect ratio of 44 glenoids from deceased donors. Glenoid size was analyzed using a 3-dimensional (3D) computed tomography (CT) scan in 24 patients with recurrent shoulder dislocation who underwent arthroscopic Bankart repair. We measured the distances from the center of the longitudinal axis of the glenoid to the anterior glenoid rim at 9 positions, 10° apart, from 3:00 to 6:00 o'clock positions in the cadaver and patient groups. We compared the quantification of glenoid defects in the 24 patients using the 3D CT scan. A predictive model based on a discriminant analysis was developed.

RESULTS

The largest length differences of the glenoid were at the 3:20 o'clock position. When percentage of bone antidefect of the 3:20 o'clock position was used, the model predicted the existence of a defect with 89.7% hit ratio.

CONCLUSIONS

The major direction of the glenoid defect was in a more anterior position rather than the anteroinferior glenoid in patients with recurrent shoulder dislocation. The 3:20 o'clock position was most common location of glenoid defect in shoulder instability. This pattern of bone loss should be considered by the surgeon when operating on these patients, especially when performing arthroscopic procedures for Bankart repair or bone block operations to the glenoid.

Для цитирования: Ji Jong-Hun, Kwak Dai-Soon, Yang Po-Song, Kwon Min Jeong, Han Seung-Ho, Jeong Jae-Jung. Comparisons of glenoid bony defects between normal cadaveric specimens and patients with recurrent shoulder dislocation: an anatomic study.. Journal of shoulder and elbow surgery. 2011. DOI: 10.1016/j.jse.2011.10.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.