MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000050545

Медицинская библиотека · Medicine · 2026

Reconstruction of a 2‑year neglected chronic patellar tendon rupture using peroneus longus autograft with suture anchor and cerclage wire augmentation: A case report and technical note.

Yang Mao-Yi, Hung Li-Wei

СтатьяКлинический случайПеревод в очереди

Аннотация

RATIONALE: Chronic patellar tendon rupture with complete tendon loss is difficult to reconstruct when primary repair is impossible. We report reconstruction using an ipsilateral peroneus longus (PL) autograft in a 4-strand "M-shaped" configuration with suture-anchor fixation and temporary cerclage augmentation.

PATIENT CONCERNS: A 17-year-old male had progressive anterior knee pain, instability, and inability to actively extend the left knee for 2 years after trauma.

DIAGNOSES: Examination showed patella alta, a palpable infrapatellar gap, and complete loss of active extension. Radiographs showed an Insall-Salvati ratio of 1.28. Magnetic resonance imaging confirmed chronic complete patellar tendon rupture without a repairable stump.

INTERVENTIONS: A 21-cm ipsilateral PL autograft was folded into a 4-strand construct and anchored to the inferior patella and tibial tubercle. Patellar height was deliberately overcorrected, and a transpatellar-tibial cerclage wire protected the reconstruction during staged rehabilitation.

OUTCOMES: At 1 year, after wire removal, the Insall-Salvati ratio was 1.08. The patient regained full active extension without lag, near-full flexion, and recreational activity participation without pain or donor-site morbidity. Asymptomatic wire breakage occurred at 6 months.

LESSONS: A multi-strand PL autograft with anchor fixation and temporary cerclage augmentation may restore patellar height and extensor function in chronic patellar tendon rupture with complete tendon loss.

Для цитирования: Yang Mao-Yi, Hung Li-Wei. Reconstruction of a 2‑year neglected chronic patellar tendon rupture using peroneus longus autograft with suture anchor and cerclage wire augmentation: A case report and technical note.. Medicine. 2026. DOI: 10.1097/md.0000000000050545.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.