MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/jss.2018.06.17

Медицинская библиотека · Journal of spine surgery (Hong Kong) · 2018

Decreasing radiation dose with FluoroLESS Standalone Anterior Cervical Fusion.

Chin Kingsley R, Pencle Fabio J R, Quijada Kathleen A, Mustafa Moawiah S, Mustafa Luai S, Seale Jason A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Radiation dose continues to be a concern especially in the field of spine surgery, where anterior and posterior instrumentation is frequently utilized to treat multiple pathologies. The authors aim to demonstrate the feasibility of decreasing the radiation dose in standalone anterior cervical discectomy and fusion (ACDF).

METHODS

Standalone ACDF (S-ACDF) with 48 consecutive patients (Group 1) with a comparison control group with ACDF with an anterior cervical plate (ACP) of 49 patients (Group 2). Fluoroscopy was performed for positioning, identification of level, placement of the implant, each screw, final AP and lateral images for the first 20 patients in Group 1. Screw placement could then be performed confidently based on cosine rule of cosine (Ѳ) = adj/hyp.

RESULTS

Forty-eight patients in Group 1 (S-ACDF) and 49 patients in Group 2 (ACDF-ACP). Statistical significance not demonstrated for age, BMI or gender, P=0.691, 0.947 and 0.286 respectively. Mean radiation dose in group 1 of 17.9±6.6 mAs and 0.8±0.3 mSv was significantly less compared to group 2 which was 29.8±5.4 and 1.3±0.2 mSv, P<0.001. The average radiation dose for single-level fusion in Group 1 was 12.5±3.5 mAs and 0.5±0.1 mSv this is compared to Group 2 of 27.8±3.9 mAs and 1.2±0.2 mSv, P=0.001. The average radiation dose for two level fusion in Group 1 was 22.2±5.1 mAs and 0.9±0.2 mSv this is compared to Group 2 of 33.9±6.0 and 1.4±0.3 mSv, P=0.001.

CONCLUSIONS

In the outpatient setting, S-ACDF has shown a statistically significant intergroup difference in overall radiation dose, as well as single and two-level fusions, (P<0.001). We conclude that S-ACDF can decrease overall radiation exposure to patients.

Для цитирования: Chin Kingsley R, Pencle Fabio J R, Quijada Kathleen A, Mustafa Moawiah S, Mustafa Luai S, Seale Jason A. Decreasing radiation dose with FluoroLESS Standalone Anterior Cervical Fusion.. Journal of spine surgery (Hong Kong). 2018. DOI: 10.21037/jss.2018.06.17.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.