Portela Diego A, McKenzie Stuart R, Moura Raiane A, Gonzalez Margaret, Donati Pablo A, Sandez Ignacio, Araos Joaquin, Chiavaccini Ludovica, Maxwell Elizabeth A, Otero Pablo E

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the effect of 5 cmH2O positive end-expiratory pressure (PEEP) and end-inspiratory pause (EIP) on airway dead space (VDaw) and its resultant effects on alveolar tidal volume (VTalv) and physiological dead space-to-tidal volume ratio (VD/VT) in dorsally recumbent anesthetized dogs.

STUDY

DESIGN

Prospective, controlled clinical study.

ANIMALS: Healthy adult dogs (n = 20, > 20 kg) undergoing elective surgery.

METHODS

Dogs were mechanically ventilated across three 5 minute phases: 1) without PEEP (PEEPOFF); 2) with 5 cmH2O PEEP (PEEPON); and 3) with PEEPON plus an EIP (30% of inspiratory time) (PEEPON+EIP), allowing 15 minutes of stabilization between phases. During each phase, expired CO2 tension and tidal volume (VT) were measured using volumetric capnography, and arterial blood gases assessed. VDaw, VTalv and VD/VT were calculated offline and compared between phases using mixed-effect linear models. Data are presented as mean ± standard deviation (95% confidence interval) and indexed to the predicted ideal body mass when appropriate.

RESULTS

The VT was 16.8 ± 1.7 (16.3-17.19) mL kg-1. PEEPON significantly increased VDaw [7.9 ± 1.6 (7.1-8.6) to 8.4 ± 1.8 (7.6-9.3) mL kg-1; p = 0.001] and VD/VT [0.52 ± 0.1 (0.49-0.55)% to 0.55 ± 0.1 (0.52-0.59)%; p = 0.001]. PEEPON decreased VTalv [8.9 ± 0.8 (8.6-9.4) to 8.3 ± 0.8 (7.9-8.7) mL kg-1; p = 0.001]. EIP reversed these changes, decreasing VDaw back to baseline [7.8 ± 1.6 (7.1-8.6) mL kg-1], resulting in VD/VT and VTalv returning to baseline values. Arterial PaCO2 remained stable across phases.

CONCLUSIONS AND CLINICAL RELEVANCE: Although PEEP increased VDaw and decreased VTalv, the addition of a 30% EIP mitigated these effects, suggesting that incorporating an EIP may be an effective strategy to optimize dead space and ventilation in dogs receiving mechanical ventilation with PEEP.

Для цитирования: Portela Diego A, McKenzie Stuart R, Moura Raiane A, Gonzalez Margaret, Donati Pablo A, Sandez Ignacio, Araos Joaquin, Chiavaccini Ludovica, Maxwell Elizabeth A, Otero Pablo E. The effects of positive end-expiratory pressure and end-inspiratory pause on dead space and alveolar ventilation in mechanically ventilated dogs.. Veterinary anaesthesia and analgesia. 2025. DOI: 10.1016/j.vaa.2025.08.038.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.