Ultrasound as a screening tool for proceeding with caudal epidural injections.

Chen Carl P, Wong Alice M, Hsu Chih-Chin, Tsai Wen-Chung, Chang Chen-Nen, Lin Shih-Cherng, Huang Yin-Cheng, Chang Chih-Hsiang, Tang Simon F

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To study the anatomical structure of the sacral hiatus using ultrasound. Based on the sonographic images of the sacral hiatus, the feasibility of caudal epidural injection can then be assessed.

DESIGN

Case-controlled study.

SETTING

Rehabilitation outpatient clinic in a tertiary medical center.

PARTICIPANTS

Patients (N=47; 20 women, 27 men) with low back pain and sciatica who were to receive caudal epidural injection treatments were recruited into this study.

INTERVENTIONS: Sonographic images of the sacral hiatus were obtained from all the patients. An ultrasound machine capable of examining musculoskeletal tissues with real-time linear-array ultrasound transducer was used to measure the distance between the anterior wall and posterior wall of the sacral hiatus (diameter of the sacral hiatus) and the distance between bilateral cornua.

MAIN OUTCOME MEASURES: Diameter of the sacral canal and distance between bilateral cornua measured in millimeters.

RESULTS

The mean diameter of the sacral canal was measured to be 5.3+/-2.0 mm in our recruited patients. The mean distance between bilateral cornua was measured to be 9.7+/-1.9 mm. Caudal epidural injections failed in 7 patients. In these 7 patients, 4 had very small diameter of the sacral canal (1.6, 1.2, 1.4, and 1.5 mm). In 1 man, sonographic images revealed a closed sacral hiatus (no sacral canal diameter can be measured). Two patients revealed flow of fresh blood into the syringe while checking for the escape of cerebrospinal fluid after the needles were inserted into the sacral canal. For safety reasons, steroid injections were not performed in these 2 patients.

CONCLUSIONS

Ultrasound may be used as an effective screening tool for caudal epidural injections. Anatomic variations of the sacral hiatus can be clearly observed using ultrasound. Sonographic images indicating a closed sacral canal and sacral diameters ranging from 1.2 to 1.6mm may suggest a higher failure rate in caudal epidural injection.

Для цитирования: Chen Carl P, Wong Alice M, Hsu Chih-Chin, Tsai Wen-Chung, Chang Chen-Nen, Lin Shih-Cherng, Huang Yin-Cheng, Chang Chih-Hsiang, Tang Simon F. Ultrasound as a screening tool for proceeding with caudal epidural injections.. Archives of physical medicine and rehabilitation. 2010. DOI: 10.1016/j.apmr.2009.11.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.