The validation of computed tomography derived radiodensity measurements of bone healing using histopathology.

Davey Jack Stewart, Rotne Randi, Edwards Glenn

СтатьяВалидационное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The early identification of delayed bone healing or a non-union is vital for prompt treatment and superior patient outcomes. Current techniques rely heavily on operator skill for interpretation and hence their reliability and repeatability may be inconsistent. This study assessed the application of computed tomography (CT) derived densiometric measurements as a quantitative tool for the assessment of bone healing.

METHODS

This prospective, longitudinal, method comparison study was performed using a recognised sheep tibial ostectomy model. Secondary bone healing was assessed at 2, 4, 6, and 8 weeks after the ostectomy was performed. CT densiometric measures of bone healing (Hounsfield units) were taken of the cis, trans, cranial and caudal cortices relative to the bone plate, with histological measurements (percentage of ossification) sourced from the same areas. Cis cortical densiometric data points were excluded from analysis due to significant beam hardening artefact from the bone plate (P < 0.001). A univariable linear regression was performed on the remaining data using averaged radiodensity (independent variable) and histomorphometric (dependent variable) measurements.

RESULTS

The two measurements were significantly correlated (R2 = 0.623, P = 0.020) with a clear positive trend identified.

CONCLUSION

This study suggests that radiodensity measurements may be a useful diagnostic and management tool for the monitoring of indirect bone healing.

Для цитирования: Davey Jack Stewart, Rotne Randi, Edwards Glenn. The validation of computed tomography derived radiodensity measurements of bone healing using histopathology.. Injury. 2024. DOI: 10.1016/j.injury.2024.111543.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.