MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/cvi.00218-07

Медицинская библиотека · Clinical and vaccine immunology : CVI · 2007

Rapid, sensitive, and specific lateral-flow immunochromatographic point-of-care device for detection of herpes simplex virus type 2-specific immunoglobulin G antibodies in serum and whole blood.

Laderman Elisabeth I, Whitworth Emma, Dumaual Erickson, Jones Mark, Hudak Andrew, Hogrefe Wayne, Carney Jim, Groen Jan

СтатьяПеревод в очереди

Аннотация

Herpes simplex virus type 2 (HSV-2) is a common human pathogen that can cause a variety of clinical manifestations in humans. In order to provide near-patient results to allow for faster counseling and treatment, a rapid point-of-care test that is accurate and simple to use is desirable. Here, we describe the development and evaluation of an HSV-2 immunoglobulin G (IgG)-specific antibody lateral-flow immunochromatographic assay (LFIA) based on colloidal gold nanoparticles. A total of 359 serum samples and 100 whole-blood samples were tested in the newly developed HSV-2 LFIA. Serum results were compared to those from the HerpeSelect HSV-2 enzyme-linked immunosorbent assay (ELISA), and whole-blood sample results were compared to those of both ELISA and HerpeSelect HSV-1 and -2 immunoblotting (IB). The sensitivity of the HSV-2 LFIA compared to that of the HerpeSelect ELISA was 100% (89/89), and the specificity was 97.3% (257/264). Cross-reactivity with HSV-1 IgG-positive serum samples was observed in 2.6% (5/196) of samples, 2.9% (1/34) for rubella virus, and 6.2% (1/16) for Epstein-Barr virus. No cross-reactivity in varicella-zoster virus or cytomegalovirus IgG-positive serum samples was observed. No interference was observed from bilirubin-, triglyceride-, albumin-, or hemoglobin-spiked samples. The concordance of the LFIA results between capillary whole blood, EDTA-treated venous whole blood, heparin-treated venous whole blood, and serum was 99% (99/100). In conclusion, the LFIA for HSV-2 IgG-specific antibodies demonstrated excellent sensitivity, specificity, and concordance for both serum and whole-blood samples compared to the sensitivity, specificity, and concordance of both HSV-2 ELISA and IB.

Для цитирования: Laderman Elisabeth I, Whitworth Emma, Dumaual Erickson, Jones Mark, Hudak Andrew, Hogrefe Wayne, Carney Jim, Groen Jan. Rapid, sensitive, and specific lateral-flow immunochromatographic point-of-care device for detection of herpes simplex virus type 2-specific immunoglobulin G antibodies in serum and whole blood.. Clinical and vaccine immunology : CVI. 2007. DOI: 10.1128/cvi.00218-07.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.