DOI 10.1016/j.ijsu.2019.03.019
Outcomes of distal femoral fractures treated with minimally invasive plate osteosynthesis versus open reduction internal fixation with combined locking plate and interfragmentary screws.
Аннотация
PURPOSE: Fractures of the distal femur remain challenging to treat, and numerous fixation methods are designed to promote stability and fracture healing. Locking plate constructs have recently become the mainstream fixation method, but debate exists on whether to use locking plates alone or to augment them with interfragmentary screws. This article compares outcomes of distal femur fractures treated with a single locking plate alone versus those treated with a locking plate and interfragmentary screws.
METHODS
We retrospectively reviewed 57 patients treated for distal femur fractures from 2010 to 2013. Patients were divided into two groups: Those treated with a locking plate alone utilizing the minimally invasive plate osteosynthesis (MIPO) technique and those treated with combination of a locking plate and interfragmentary screws using an open technique. Postoperative outcomes were obtained via a manual chart review. Fracture healing and callus indices were evaluated from radiographs.
RESULTS
9 patients required revision surgery in the locking plate alone group (6 for persistent nonunion and 3 for varus deformity). Only two patients in the combination group required revisions (both for nonunion). Average time to full weight bearing was 19.54 weeks in the locking plate group versus 14.57 weeks in the combination group (p = 0.004). At the time of full weight bearing, frontal (1.15 versus 1.11, p = 0.004) and sagittal (1.22 versus 1.15, P = 0.008) callus indices were both significantly greater in the locking plate group.
CONCLUSIONS
In this study, the combination of a locking plate and interfragmentary screws achieved suitable stability and a faster time to full weight bearing than using a locking plate alone. Surgeons should consider combining a locking plate with interfragmentary screws as an effective method for fixation of distal femur fractures, particularly in cases when plate fixation alone fails to provide adequate fracture stability.