MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2192568219850143

Медицинская библиотека · Global spine journal · 2019

The Effect of Thoracolumbar Pedicle Isthmus on Pedicle Screw Accuracy.

Raasck Kyle, Khoury Jason, Aoude Ahmed, Beland Benjamin, Munteanu Alexander, Weber Michael H, Golan Jeff

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective analysis.

OBJECTIVES

Aberrant pedicle screws can cause serious neurovascular complications. We propose that a predominant factor of pedicle screw breach is the vertebral anatomy at a given spinal level. We aim to investigate the inverse correlation between breach incidence and vertebral isthmus width.

METHODS

The computed tomography scans of patients undergoing thoracolumbar surgery were retrospectively reviewed. Breaches were categorized as minor (<2 mm) or major (>2 mm). Breach incidence was stratified by spinal level. Average isthmus width was then compared to the collected breach incidences. A regression analysis and Pearson's correlation were performed.

RESULTS

A total of 656 pedicle screws were placed in 91 patients with 233 detected breaches. Incidence of major breach was 6.3%. Four patients developed post-operative radiculopathy due to breach. Breach incidence was higher in the thoracic than lumbar spine (Fisher's exact test, P < .0001). The 2 spinal levels with the thinnest isthmus width (T4 and T5) were breached most often (73.7% and 73.9%, respectively). The 2 spinal levels with the thickest isthmus width (L4 and L5) were breached least often (20.5% and 11.8%). Breach incidence and isthmus width were shown to have a significant inverse correlation (Pearson's correlation, R 2 = 0.7, P < .0001).

CONCLUSIONS

Thinner vertebral isthmus width increases pedicle screw breach incidence. Image-guided assistance may be most useful where breach incidence is highest and isthmus width is lowest (T2 to T6). Despite high incidence of cortical bone violation, there was little correlation with clinical symptoms. A breach is not automatically a clinical problem, provided the screw is structurally sound and the patient is symptomless.

Для цитирования: Raasck Kyle, Khoury Jason, Aoude Ahmed, Beland Benjamin, Munteanu Alexander, Weber Michael H, Golan Jeff. The Effect of Thoracolumbar Pedicle Isthmus on Pedicle Screw Accuracy.. Global spine journal. 2019. DOI: 10.1177/2192568219850143.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.