DOI 10.1016/j.injury.2017.10.029
Sliding hip screw versus intramedullary nail for trochanteric hip fractures; a randomised trial of 1000 patients with presentation of results related to fracture stability.
Аннотация
AIMS: To determine the optimum choice of implant for a patient with a the different types of trochanteric hip fracture.
PATIENTS AND
METHODS
1000 patients with a trochanteric hip fracture were randomised to internal fixation of the fracture with either a Sliding Hip Screw or an intramedullary nail. Fractures were subdivided into two part fractures, comminuted fractures and fractures at the level of the lesser trochanter (reversed/oblique and transverse). Functional assessment for up to one year from injury was undertaken by a research nurse blinded to the treatment allocation.
RESULTS
The mean age of patients was 82years and 77% were female. There was a significantly improved regain of mobility for those treated with the intramedullary nail. No statistically significant differences between the two types of fixation methods was observed for mortality, fracture healing complications, re-operations, hospital stay, length of surgery, blood transfusion requirements, medical complications, degree of residual pain or regain of independence. These finding were valid for all fracture types.
CONCLUSION
This study is the first adequately powered randomised trial on this topic and demonstrates that there are no notable differences in either process or functional outcomes between these two treatment methods, other than a tendency to better regain of mobility for those fractures fixed with an intramedullary nail.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.