MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsbiomaterials.4c00631

Медицинская библиотека · ACS biomaterials science & engineering · 2024

Conductive/Insulating Bioinks with Multitechnology Compatibility and Adjustable Performance.

Yang Xi, Zhong Yufan, Zhang Liang, Liu Yulu, Zhuo Fengling, Wang Jianmin, Ge Linyan, Zhang Liuhang, Zeng Xiangyu, Tan Weiqiang, Song Guanghui, Zhang Hua, Wang Xiaozhi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Conducting/insulating inks have received significant attention for the fabrication of a wide range of additive manufacturing technology. However, current inks often demonstrate poor biocompatibility and face trade-offs between conductivity and mechanical stiffness under physiological conditions. Here, conductive/insulating bioinks based on two-dimensional materials are proposed. The conductive bioink, graphene (GR)-poly(lactic-co-glycolic acid) (PLGA), is prepared by introducing conductive GR into a degradable polymer matrix, PLGA, while the insulating bioink, boron nitride (BN)-PLGA, is synthesized by adding insulating BN. By optimizing the material ratios, this work achieves precise control of the electromechanical properties of the bioinks, thereby enabling the flexible construction of conductive networks according to specific requirements. Furthermore, these bioinks are compatible with a variety of manufacturing technologies such as 3D printing, electrospinning, spin coating, and injection molding, expanding their application range in the biomedical field. Overall, the results suggest that these conducting/insulating bioinks offer improved mechanical, electronic, and biological properties for various emerging biomedical applications.

Для цитирования: Yang Xi, Zhong Yufan, Zhang Liang, Liu Yulu, Zhuo Fengling, Wang Jianmin, Ge Linyan, Zhang Liuhang, Zeng Xiangyu, Tan Weiqiang, Song Guanghui, Zhang Hua, Wang Xiaozhi. Conductive/Insulating Bioinks with Multitechnology Compatibility and Adjustable Performance.. ACS biomaterials science & engineering. 2024. DOI: 10.1021/acsbiomaterials.4c00631.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.