Bedside ultrasonography for verification of shoulder reduction: A long way to go.

Ahmadi Koorosh, Hashemian Amir-Masoud, Sineh-Sepehr Kaveh, Afzal-Aghaee Monavvar, Jafarpour Saba, Rahimi-Movaghar Vafa

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Shoulder dislocation is a common joint dislocation managed by the emergency physicians in the emergency departments. Pre- and post-reduction radiographic examinations have long been the standard practice to confirm the presence of dislocation and the successful reduction. However, shoulder ultrasonography has recently been proposed as an alternative to the radiographic examination. This study aimed to assess the accuracy of ultrasonography in evaluating proper reduction of the dislocated joint.

METHODS

This was a prospective observational study. All patients with confirmed anterior shoulder dislocation were examined by both ultrasonography and radiography after the attempt for reduction of the dislocated joint. The examiners were blinded to the result of the other imaging modality. Results of the two methods were then compared.

RESULTS

Overall, 108 patients with confirmed anterior shoulder dislocation were enrolled in the study. Ninety-one (84.3%) of the patients were males. Mean age of the participants was (30.11 ± 11.41) years. The majority of the patients had a recurrent dislocation. Bedside ultrasonography showed a sensitivity of 53.8% (95% CI: 29.1%-76.8%) and a specificity of 100% (95% CI: 96.1%-100%) in detecting inadequate reductions. The results of ultrasonography had a statistically significant agreement with the results of radiography (Kappa = 0.672, p < 0.001).

CONCLUSION

The results suggest that the sensitivity of post-reduction ultrasound is not sufficient for it to serve as a substitute for radiography.

Для цитирования: Ahmadi Koorosh, Hashemian Amir-Masoud, Sineh-Sepehr Kaveh, Afzal-Aghaee Monavvar, Jafarpour Saba, Rahimi-Movaghar Vafa. Bedside ultrasonography for verification of shoulder reduction: A long way to go.. Chinese journal of traumatology = Zhonghua chuang shang za zhi. 2016. DOI: 10.1016/j.cjtee.2015.07.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.