Functional Outcome of Intra-Articular Distal End Radius Fracture Treated Surgically by Volar Locking Plate: A Prospective Study.
Аннотация
BACKGROUND
Unstable distal end intra-articular fractures of the radius pose a greater risk of reduction loss, potentially resulting in malunion and poor functional outcomes. Therefore, the amount of reduction and the technique of fracture fixation play a crucial role in achieving improved functional outcomes and ensuring patient satisfaction.
MATERIAL AND
METHODS
This is a study of prospectively enrolled 27 patients with displaced intra-articular distal end radius fractures treated surgically by volar locking plate through modified Henry's approach in the department of orthopedics at a tertiary care center. Patients were post-operatively evaluated for functional outcome and complications.
RESULTS
Out of the 27 patients 26 came for regular follow up, ranging from 3 months to 18 months and one patient was lost to follow-up. The functional outcome was investigated with the Mayo wrist score. Excellent scores were noted in 34.6%, good in 53.8% and satisfactory in 11.5% of the patients.
CONCLUSION
Irrespective of the direction and degree of displacement, the volar locking plate as a treatment for an intraarticular distal end radius fracture is a good option as it provides stable fixation, and good to excellent outcomes with less complications.