Effective prevention of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip arthroplasty using a posterior lip augmentation device.

Schmidl S, Jakobs O, Guenther D, Lausmann C, Schoof B, Beckmann J, Gehrke T, Gebauer M

СтатьяПеревод в очереди

Аннотация

PURPOSE: This retrospective study was performed to determine the effectiveness of preventing recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device (PLAD).

METHODS

Between January 2003 and Dezember 2006, 27 PLADs were used in the treatment of recurrent hip dislocation in 27 patients who had received a cemented primary total hip arthroplasty using Endo-MarkIII/SP2 (Waldemar LINK, Hamburg, Germany) components. The mean number of dislocations prior to stabilization with this specific device was 2.6 (range 2-4, SD ± 0.4) with a mean time to revision surgery of 10 months (IQR 13). The mean age of the patients at time of revision surgery was 81.5 years (range 70-94, SD ± 6.9). The control group evaluating the clinical outcome using the Harris Hip Score (HHS) also received a cemented primary total hip arthroplasty using the same implants. A retrospective clinical and radiological review was carried out at a mean follow-up of 68.5 months (range 30-103, SD ± 17.7).

RESULTS

Of the 27 patients, 6 had died at the time of the latest review, with the posterior lip augmentation device still in situ and without reported further dislocation after PLAD application. In 2 of the remaining 21 patients recurrent dislocation occurred, thus a subsequent revision of respective implants had to be performed to achieve persistent joint stability. At latest follow-up no deep infection or implant loosening occurred.

CONCLUSION

Surgical treatment of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip replacement using a posterior lip augmentation device is a safe and effective procedure which can lead to a secondary stabilization of the total hip arthroplasty in about 90 % of the patients.

Для цитирования: Schmidl S, Jakobs O, Guenther D, Lausmann C, Schoof B, Beckmann J, Gehrke T, Gebauer M. Effective prevention of recurrent dislocation following primary cemented Endo-MarkIII/SP2 total hip arthroplasty using a posterior lip augmentation device.. Archives of orthopaedic and trauma surgery. 2016. DOI: 10.1007/s00402-016-2415-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.