MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13018-020-01584-y

Медицинская библиотека · Journal of orthopaedic surgery and research · 2020

Syndesmotic malreduction may decrease fixation stability: a biomechanical study.

Bai Lu, Zhang Wentao, Guan Siyao, Liu Jianxin, Chen Peng

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This study aims to investigate the malreduction of syndesmosis and its effects on stability.

METHODS

The biomechanical tests, including the three-dimensional (3D) displacement of the syndesmotic incisura, fibular rotation angle, and torque resistance, were performed on six cadaver legs. These specimens were first tested intact (intact group), then cut all the syndesmotic ligaments and fixed in anatomical position (anatomical model group) and test again. After that, syndesmosis was fixed in 1 cm malreduction (anterior and posterior displacement group) to do the same test.

RESULTS

In internal or external load, there were significant differences in torque resistance and fibular rotation angle (internal t = 2.412, P = 0.036; external t = 2.412, P = 0.039) between the intact and post-malreduction groups. In internal rotation load, there were significant differences in sagittal displacement between the intact and post-malreduction groups (P = 0.011), and between the anatomical and post-malreduction groups (P = 0.020). In external rotation load, significant differences existed between the intact and ant-malreduction group (P = 0.034) in sagittal (anterior-posterior) displacement. Significant differences also existed between the intact and post-malreduction groups (P = 0.013), and between the anatomical and post-malreduction groups (P = 0.038) in coronal (medial-lateral) displacement.

CONCLUSIONS

Malreduction in different conditions does affect the stability of the syndesmotic fixation. The result of the study may reveal the biomechanical mechanism of poor clinical outcome in syndesmosis malreduction patients and pathological displacement patterns of the ankle under syndesmotic malreduction conditions.

LEVEL OF EVIDENCE: III.

Для цитирования: Bai Lu, Zhang Wentao, Guan Siyao, Liu Jianxin, Chen Peng. Syndesmotic malreduction may decrease fixation stability: a biomechanical study.. Journal of orthopaedic surgery and research. 2020. DOI: 10.1186/s13018-020-01584-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.