m+Medelevator.RU
← Поиск публикаций
The Journal of bone and joint surgery. American volume · 2021

Validation of the Alpha Defensin Lateral Flow Test for Periprosthetic Joint Infection.

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеВалидационное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Deirmengian Carl, Madigan John, Kallur Mallikarjuna Sujith, Conway Janet, Higuera Carlos, Patel Robin

Аннотация

BACKGROUND: The synovial fluid test for alpha defensin has been reported to have an excellent performance in diagnosing periprosthetic joint infection (PJI). The purpose of this study was to evaluate the performance of the lateral flow test for synovial fluid alpha defensin by using the methods of a formal diagnostic accuracy study and to compare its performance with that of the laboratory-based alpha defensin test for PJI.

METHODS: We conducted a diagnostic accuracy study of the index lateral flow immunoassay for synovial fluid alpha defensin relative to the reference 2013 Musculoskeletal Infection Society (MSIS) multicriteria definition of PJI. The study included a prospective multicenter cohort of outpatients with a failed hip or knee arthroplasty and a supplemental control cohort of fresh synovial fluid specimens submitted by physicians for diagnostic PJI testing.

RESULTS: Among 57 patients with PJI and 248 patients without PJI in the overall prospective patient cohort, the sensitivity and specificity of the alpha defensin lateral flow test were 89.5% (95% confidence interval [CI]: 78.5% to 96.0%) and 94.8% (95% CI: 91.2% to 97.2%), respectively. The sensitivity increased to 94.3% (95% CI: 84.3% to 98.8%) after exclusion of 17 patients with grossly bloody aspirates (>1 million red blood cells/µL). Among the supplemental control cohort of fresh synovial fluid samples, including 65 samples from patients with PJI and 397 from patients without PJI, the sensitivity and specificity of the alpha defensin lateral flow test were 98.5% (95% CI: 91.7% to 100.0%) and 98.2% (95% CI: 96.4% to 99.3%), respectively. A comparison of the sensitivity and specificity of the alpha defensin lateral flow test with those of the alpha defensin enzyme-linked immunosorbent assay (ELISA) in the combined cohort did not demonstrate a significant difference in sensitivity (94.3% [95% CI: 88.5% to 97.7%] compared with 93.0% [95% CI: 87.1% to 96.7%]) or specificity (96.9% [95% CI: 95.3% to 98.1%] compared with 97.8% [95% CI: 96.4% to 98.8%]) (both p > 0.05).

CONCLUSIONS: The results of this study demonstrate the solid diagnostic performance of the alpha defensin test and have resulted in the U.S. Food and Drug Administration (FDA) authorization of the lateral-flow test with an intended use as an aid in the clinical diagnosis of PJI.

LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты