MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00068-025-02794-x

Медицинская библиотека · European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025

Clavicle refractures after hardware removal: are there risk factors? A retrospective cohort study.

Kessler Franziska, Kalbas Yannik, Hambrecht Jan, Wlach Victoria, Halvachizadeh Sascha, Pfeifer Roman, Pape Hans-Christoph, Klingebiel Felix Karl-Ludwig, Hierholzer Christian

СтатьяПеревод в очереди

Аннотация

PURPOSE: Removal of symptomatic hardware after fracture fixation is common, especially in patients with clavicle fracture. Yet, refracture after hardware removal is a relatively common complication in those patients. The aim of this study was to identify risk factors for clavicle refractures that could be influenced by the surgical treatment provided.

METHODS

All patients from a level one trauma center from 2017 to 2022 were screened for eligibility. Inclusion criteria included hardware removal after plate osteosynthesis of the clavicle, age ≥ 18 years, and signed informed consent. Groups were stratified according to occurrence of refracture: no-refracture (NR) vs. refracture (R). Nearest-neighbor matching in a ratio of 5:1 was performed. Parameter investigated included baseline demographics, fracture characteristics and surgical treatment details. A subgroup analysis of only clavicle shaft fractures was performed.

RESULTS

Sixty patients were included with 50 patients in Group NR and 10 in Group R. Baseline characteristics were comparable between the groups. A subgroup analysis on shaft fractures revealed that a significantly larger working length (number of empty screw holes adjacent to the fracture site) in Group NR (1.94 ± 0.85) compared to the refracture group (1.20 ± 0.92) (p = 0.042). Logistic regression yielded an inverse correlation with the number of empty screw holes to the fracture site and the occurrence of refractures (OR 0.369, 95% CI 0.132-0.873; p = 0.035). Time in situ, lag screw application, plate positioning and the total amount of screws did not affect either of the groups.

CONCLUSION

An increased working length in patients with clavicle shaft fractures might be a protective measure for occurrence of refractures after hardware removal.

Для цитирования: Kessler Franziska, Kalbas Yannik, Hambrecht Jan, Wlach Victoria, Halvachizadeh Sascha, Pfeifer Roman, Pape Hans-Christoph, Klingebiel Felix Karl-Ludwig, Hierholzer Christian. Clavicle refractures after hardware removal: are there risk factors? A retrospective cohort study.. European journal of trauma and emergency surgery : official publication of the European Trauma Society. 2025. DOI: 10.1007/s00068-025-02794-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.