An ELISA system to detect anti-factor VIII antibodies without interference by lupus anticoagulants. Preliminary data in hemophilia A patients.

Blanco A N, Peirano A A, Grosso S H, Gennari L C, Bianco R P, Lazzari M A

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Difficulties in identifying the coexistence of neutralizing anti-factor VIII antibodies (anti-fVIII) and lupus anticoagulant (LA) are mainly due to the interference of LA on anti-fVIII assays. Our aim was to reveal the presence of anti-fVIII using a system that is not affected by LA.

DESIGN AND

METHODS

We developed an enzyme-linked immunosorbent assay (ELISA) method that uses phospholipid-free recombinant factor VIII as the antigen. A monoclonal anti-fVIII was tested as a positive control, excluding non-specific binding by using two unrelated monoclonal antibodies. The ELISA was performed on hemophilic plasmas with anti-fVIII and negative LA (n=12) or without inhibitors (n=12). Two hemophilic plasmas with LA and presumably anti-fVIII were also assayed. Positive LA (n=12) and normal (n=10) plasmas were tested as negative controls.

RESULTS

All (12/12) plasmas with anti-fVIII and 5/12 hemophilic plasmas without inhibitors were positive; LA and normal plasma controls were negative.

INTERPRETATION AND

CONCLUSIONS

Results presented here show that LA does not interfere with the anti-fVIII ELISA: However, the assay detects both neutralizing and non-neutralizing anti-fVIII antibodies, therefore a neutralizing effect must be confirmed through functional tests.

Для цитирования: Blanco A N, Peirano A A, Grosso S H, Gennari L C, Bianco R P, Lazzari M A. An ELISA system to detect anti-factor VIII antibodies without interference by lupus anticoagulants. Preliminary data in hemophilia A patients.. Haematologica. 2000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.