Objective Monitoring of Jewett Brace Compliance in Osteoporotic Vertebral Fractures: A Prospective Sensor-Based Study.

Funayama Toru, Sato Kosuke, Shibao Yosuke, Ogata Yosuke, Okuwaki Shun, Gamada Hisanori, Nakagawa Takane, Miura Kousei, Takahashi Hiroshi, Noguchi Hiroshi, Tatsumura Masaki, Koda Masao

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Osteoporotic vertebral fractures (OVFs) are the most common type of fragility fracture in elderly patients with osteoporosis. Bracing is widely used for conservative treatment; however, few studies have objectively assessed patient adherence to prescribed brace usage. This prospective study aimed to evaluate true patient compliance with the Jewett brace for acute OVFs using a temperature logger embedded in the brace.

METHODS

Patients aged ≥65 years with an acute OVF diagnosed within two weeks of injury were enrolled between February 2024 and January 2025. After two weeks of bed rest, patients began ambulation while wearing a Jewett brace. A button-type temperature logger was installed on the sternal pad of the brace to record the temperature every 30 minutes for 42 consecutive days. Wearing was defined as temperatures ≥30°C. Based on previous reports, wearing the brace for 15 hours daily was defined as 100% compliance. Compliance was calculated for the entire period, for hospitalization versus post-discharge, and at three 14-day intervals. Correlations between vertebral instability and compliance were also analyzed.

RESULTS

A total of 17 patients were included in the final analysis. The mean overall compliance rate was 85.8%, corresponding to an average wearing time of 12.9 hours per day. Brace compliance was consistently maintained at a high level during hospitalization and after discharge, as well as across the first, second, and last 14-day intervals. The daily wearing rate peaked at approximately 80% around mealtimes and remained above 70% during daytime hours. A significant, moderately positive correlation was observed between vertebral instability and compliance in the last 14 days.

CONCLUSIONS

This study objectively demonstrated a remarkably high patient compliance rate of 85.8% (12.9 hours per day) with Jewett braces for OVFs during the 42-day period following the initial two-week hospitalized bed rest.

Для цитирования: Funayama Toru, Sato Kosuke, Shibao Yosuke, Ogata Yosuke, Okuwaki Shun, Gamada Hisanori, Nakagawa Takane, Miura Kousei, Takahashi Hiroshi, Noguchi Hiroshi, Tatsumura Masaki, Koda Masao. Objective Monitoring of Jewett Brace Compliance in Osteoporotic Vertebral Fractures: A Prospective Sensor-Based Study.. Spine surgery and related research. 2025. DOI: 10.22603/ssrr.2025-0215.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.