DOI 10.1097/rli.0000000000000671

Медицинская библиотека · Investigative radiology · 2020

X-ray Dark-Field Radiography: Potential for Visualization of Monosodium Urate Deposition.

Braig Eva-Maria, Roiser Nathalie, Kimm Melanie A, Busse Madleen, Andrejewski Jana, Scholz Josef, Petrich Christian, Gustschin Alex, Sauter Andreas, Bodden Jannis, Meurer Felix, Korbel Rüdiger, Pfeiffer Franz, Herzen Julia, Pfeiffer Daniela

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to evaluate the potential of x-ray dark-field radiography for the noninvasive detection of monosodium urate (MSU) crystals as a novel diagnostic tool for gout.

MATERIALS AND

METHODS

Contrast-to-noise ratios of MSU crystals in conventional radiography and dark-field radiography have been compared in a proof of principle measurement. Monosodium urate crystals have been injected into mouse legs in an ex vivo experimental gout setup. Three radiologists independently evaluated the images for the occurrence of crystal deposits in a blinded study for attenuation images only, dark-field images only, and with both images available for a comprehensive diagnosis. All imaging experiments have been performed at an experimental x-ray dark-field setup with a 3-grating interferometer, a rotating anode tube (50 kVp), and a photon-counting detector (effective pixel size, 166 μm).

RESULTS

X-ray dark-field radiography provided a strong signal increase for MSU crystals in a physiological buffer solution compared with conventional attenuation radiography with a contrast-to-noise ratio increase from 0.8 to 19.3. Based on conventional attenuation images only, the reader study revealed insufficient diagnostic performance (sensitivity, 11%; specificity, 92%) with poor interrater agreement (Cohen's coefficient κ = 0.031). Based on dark-field images, the sensitivity increased to 100%, specificity remained at 92%, and the interrater agreement increased to κ = 0.904. Combined diagnosis based on both image modalities maximized both sensitivity and specificity to 100% with absolute interrater agreement (κ = 1.000).

CONCLUSIONS

X-ray dark-field radiography enables the detection of MSU crystals in a mouse-based gout model. The simultaneous avaliability of a conventional attenuation image together with the dark-field image provides excellent detection rates of gout deposits with high specificity.

Для цитирования: Braig Eva-Maria, Roiser Nathalie, Kimm Melanie A, Busse Madleen, Andrejewski Jana, Scholz Josef, Petrich Christian, Gustschin Alex, Sauter Andreas, Bodden Jannis, Meurer Felix, Korbel Rüdiger, Pfeiffer Franz, Herzen Julia, Pfeiffer Daniela. X-ray Dark-Field Radiography: Potential for Visualization of Monosodium Urate Deposition.. Investigative radiology. 2020. DOI: 10.1097/rli.0000000000000671.

Предметные рубрики MeSH