MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2016.09.058

Медицинская библиотека · Journal of shoulder and elbow surgery · 2016

Interobserver and intraobserver variability of glenoid track measurements.

Schneider Adrian K, Hoy Gregory A, Ek Eugene T, Rotstein Andrew H, Tate Julie, Taylor David McD, Evans Matthew C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

A method of assessing combined glenoid and humeral bone loss in traumatic shoulder instability with an associated treatment protocol was recently published. The aim of this study was to investigate its reliability and reproducibility.

METHODS

Seventy-one patients with unilateral anteroinferior shoulder instability underwent computed tomography scans, from which 3-dimensional images were derived. En face views of both glenoid fossae and with 3 views of the humeral head were provided to 4 assessors to determine interobserver reliability. From these measurements, the shoulder was assigned a treatment classification. Two observers repeated their assessments 1 month later to determine intraobserver reliability. For each measurement, the mean coefficient of variability was calculated.

RESULTS

Assessment of glenoid bone loss showed good interobserver (4 observers agreeing in 90.1% of cases) and also good intraobserver agreement (94% and 96%). There was a poor level of interobserver reliability regarding the on-track or off-track classification (72%). Intraobserver reliability for this measurement was less variable (90% and 80%). There was a poor level of agreement between observers (65%) regarding treatment classification. The coefficient of variability for the Hill-Sachs lesion measured 19.2%, indicating a high level of variability for this measurement compared with <4% for all other measures.

CONCLUSION

Linear bone loss on the glenoid can be measured reliably and reproducibly; however, evaluation of Hill-Sachs lesions demonstrates a high level of variability, and poor interobserver reliability.

Для цитирования: Schneider Adrian K, Hoy Gregory A, Ek Eugene T, Rotstein Andrew H, Tate Julie, Taylor David McD, Evans Matthew C. Interobserver and intraobserver variability of glenoid track measurements.. Journal of shoulder and elbow surgery. 2016. DOI: 10.1016/j.jse.2016.09.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.