MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/23259671231189729

Медицинская библиотека · Orthopaedic journal of sports medicine · 2023

Portal Selection for Suture Anchor Placement During Hip Arthroscopic Labral Repair: A Study Based on 3-Dimensional Model Reconstruction.

Chen Qi, Zou Jiyang, Wang Fusheng, Qiao Kai, Li Han, Zhang Weiguo, Tian Kang

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Arthroscopic suture repair is the main treatment option for hip labral tears; however, anchor insertion and placement from arthroscopic portals is difficult.

PURPOSE: To quantitatively evaluate the safety of various arthroscopic portals for suture anchor placement during hip labral repair.

STUDY

DESIGN

Descriptive laboratory study.

METHODS

The computed tomography scans of 20 patients with normally developed hip joints were used to create 3-dimensional models. The distances from the anchor to the articular cartilage (DAC) and from the acetabular insertion point to the cortical bone (DCB) were measured in the anterolateral portal (AL), posterolateral portal (PL), midanterior portal (MAP), medial MAP, and 3 distal anterolateral accessory portals (DALAs): DALA-proximal, DALA-middle, and DALA-distal. Labral tears were divided into anterior (4, 3, and 2 o'clock), lateral (1, 12, and 11 o'clock), and posterior (10, 9, and 8 o'clock) acetabular zones, and the Kruskal-Wallis and Mann-Whitney U test were used to compare DAC and DCB in the zones. The success rate was defined as anchors placed with DAC ≥1 mm and DCB ≥15 mm.

RESULTS

The DAC was significantly smaller in the AL at 1 o'clock (0.68 ± 0.32 mm; P < .001) and 12 o'clock (0.37 ± 0.30 mm; P < .001), and in the PL at 12 o'clock (-0.35 ± 0.38 mm; P < .001) and 11 o'clock (0.60 ± 0.24 mm; P < .001). The DCB was significantly smaller in the DALA-P at 3 o'clock (8.93 ± 2.12 mm; P < .001) and 11 o'clock (9.59 ± 2.84 mm; P < .001), the MAP at 12 o'clock (13.76 ± 3.89 mm; P < .001) and 11 o'clock (0.27 ± 0.27 mm; P < .001), and the MMA at 12 o'clock (5.96 ± 2.31 mm; P < .001) and 11 o'clock (0 mm; P < .001). Success rates were high for MAP and MMA between 4 o'clock and 1 o'clock, for DALA-proximal at 12 o'clock, for AL at 11 o'clock, and for PL between 10 o'clock and 8-o'clock.

CONCLUSION

There were significant differences in the success rate of anchor placement using different portals during hip arthroscopic labral repair.

CLINICAL RELEVANCE: MAP is recommended for labral repair between 4 o'clock and 1 o'clock, DALA-P is recommended between 2 o'clock and 12 o'clock, AL is suitable at 11 o'clock, and PL is suitable between 10 o'clock and 8 o'clock.

Для цитирования: Chen Qi, Zou Jiyang, Wang Fusheng, Qiao Kai, Li Han, Zhang Weiguo, Tian Kang. Portal Selection for Suture Anchor Placement During Hip Arthroscopic Labral Repair: A Study Based on 3-Dimensional Model Reconstruction.. Orthopaedic journal of sports medicine. 2023. DOI: 10.1177/23259671231189729.