MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/pds.3786

Медицинская библиотека · Pharmacoepidemiology and drug safety · 2015

Evaluation of an ICD-10 algorithm to detect osteonecrosis of the jaw among cancer patients in the Danish National Registry of Patients.

Ehrenstein Vera, Gammelager Henrik, Schiødt Morten, Nørholt Sven Erik, Neumann-Jensen Bjarne, Folkmar Troels Bille, Pedersen Lars, Svaerke Claus, Sørensen Henrik Toft, Ma Haijun, Acquavella John

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: This study aimed to validate a predefined algorithm for osteonecrosis of the jaw (ONJ) among cancer patients in the Danish National Registry of Patients and to assess the nature of clinical information recorded in medical charts of ONJ patients.

METHODS

We identified potential ONJ cases recorded in 2005-2010 among cancer patients at the hospital Departments of Oral and Maxillofacial Surgery (DOMS) in three Danish regions, using a set of codes from the International Classification of Diseases, 10th revision (ICD-10). We abstracted DOMS charts of the potential cases, had the ONJ status adjudicated by an expert ONJ adjudication committee (ONJAC), and computed positive predictive values. For patients with ONJAC-confirmed ONJ, we abstracted the charts for information on ONJ clinical course. Sensitivity of the algorithm was computed using a separate sample of 101 known ONJ cases accrued in 2005-2011.

RESULTS

We identified 212 potential ONJ cases, of which 197 (93%) had charts available for abstraction. Eighty-three potential cases were confirmed by ONJAC, with a positive predictive value of 42% (95% confidence interval [CI] 35%-49%). DOMS charts of these 83 cases contained complete information on ONJ clinical course. Information about antiresorptive treatment was recorded for 84% of the patients. Among the 101 known ONJ cases, 74 had at least one prespecified ICD-10 code recorded in the Danish National Registry of Patients within ±90 days of the ONJ diagnosis (sensitivity 73%; 95%CI [64%-81%]).

CONCLUSIONS

The predefined algorithm is not adequate for monitoring ONJ in pharmacovigilance studies. Additional case-finding approaches, coupled with adjudication, are necessary to estimate ONJ incidence accurately.

Для цитирования: Ehrenstein Vera, Gammelager Henrik, Schiødt Morten, Nørholt Sven Erik, Neumann-Jensen Bjarne, Folkmar Troels Bille, Pedersen Lars, Svaerke Claus, Sørensen Henrik Toft, Ma Haijun, Acquavella John. Evaluation of an ICD-10 algorithm to detect osteonecrosis of the jaw among cancer patients in the Danish National Registry of Patients.. Pharmacoepidemiology and drug safety. 2015. DOI: 10.1002/pds.3786.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.