MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00392-026-03015-0

Медицинская библиотека · Clinical research in cardiology : official journal of the German Cardiac Society · 2026

Routine versus selective use of a femoral protection wire in transfemoral TAVI: a single-centre analysis of vascular complications.

Rogmann Marc Adrian, Klingemann Victor, Meertens Max, Ahoopai Majid, Rommel Karl-Philipp, Lurz Philipp, von Bardeleben Ralph S, Geyer Martin

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transfemoral transcatheter aortic valve implantation (TAVI) is the treatment of choice for severe aortic stenosis in patients with elevated surgical risk. However, vascular complications remain a major source of morbidity and mortality. The protection wire technique was introduced to prevent major access-related complications, but its role in contemporary TAVI practice is uncertain.

AIMS: To evaluate whether routine protection wire use reduces vascular complications in contemporary transfemoral TAVI.

METHODS

We performed a retrospective, single-centre analysis of 1476 consecutive patients undergoing transfemoral TAVI between January 2020 and August 2023. Until November 2021, protection wire placement was standard-of-care (Group 1, n = 801); thereafter procedures were performed without routine protection wire use (Group 2, n = 675). Vascular complications were defined according to VARC-3 criteria. Multivariable logistic regression was used to identify independent predictors of minor and major vascular complications.

RESULTS

The composite of minor and major vascular complications occurred more frequently in Group 1 than in Group 2 (18.6% vs. 10.8%, p < 0.001). In Group 1, 34.8% of access-related complications were associated with the protection wire access. Major vascular complications were numerically less frequent in Group 2 (2.5% vs. 4.2%). Omission of routine protection wire placement was independently associated with a lower risk (OR 0.52, 95% CI 0.38-0.72, p < 0.001).

CONCLUSION

In contemporary transfemoral TAVI, routine protection wire use was not associated with reduced major vascular complications and was linked to a higher rate of minor access site injuries. These findings support a restrictive rather than routine use of protection wires in current practice.

Для цитирования: Rogmann Marc Adrian, Klingemann Victor, Meertens Max, Ahoopai Majid, Rommel Karl-Philipp, Lurz Philipp, von Bardeleben Ralph S, Geyer Martin. Routine versus selective use of a femoral protection wire in transfemoral TAVI: a single-centre analysis of vascular complications.. Clinical research in cardiology : official journal of the German Cardiac Society. 2026. DOI: 10.1007/s00392-026-03015-0.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.